Maintenance and Repair
4-3
Part 1074165A02
E
2010 Nordson Corporation
Replacement Procedures
Preparation
1. Turn off the UV system from the process
equipment controller or at the UV panel.
2. Allow the lamphead fan to complete its cooling
cycle. If this has been prevented by premature
isolation of the control cabinet, always allow
sufficient time for the bulb to cool before
proceeding.
3. Turn off the main electrical disconnect. Follow
all relevant OSHA-established lockout
procedures.
4. If the lamphead has a plastic and metal
connector, disconnect the interconnect cables.
5. If necessary, loosen the lamphead mounting
fasteners and remove the assembly from the
brackets.
Bulb Replacement
1. Perform the
Preparation
procedure in this
section.
2. See Figure 4-1. Turn or place the lamphead
assembly so that the entire bulb area is
exposed and accessible.
3. Remove the eight screws from the lamphead
base to remove the RF screen.
Figure 4-1
RF Screen Removal
NOTE:
Do not touch the quartz portion of the
bulb with bare hands. Use protective gloves.
4. See Figure 4-2. Grasp the ends of the bulb and
push it to one side. Lift one end of the bulb out
of the retaining hole; the other end of the bulb
should come out of the other retaining hole.
5. Place one end of the new bulb into the retaining
hole, push to one side and lower the bulb into
place. Install the remaining end of the bulb into
the other retaining hole.
6. Place the old bulb in the new bulb packaging
and dispose of according to your company’s
disposal policies. Refer to page 1-6 in the
Safety
section for the bulb return policy.
7. Install the RF screen to the lamphead base with
the eight screws. Torque to 1.1 N
S
m (10-in. lb).
Figure 4-2
Bulb Replacement
Содержание Coolwave 610
Страница 4: ...Table of Contents ii Part 1074165A02 E 2010 Nordson Corporation...
Страница 12: ...Safety 1 8 Part 1074165A02 E 2010 Nordson Corporation...
Страница 22: ...Installation 3 6 Part 1074165A02 E 2010 Nordson Corporation...
Страница 34: ...Troubleshooting 5 2 Part 1074165A02 E 2010 Nordson Corporation...
Страница 40: ...Parts 6 6 Part 1074165A02 E 2010 Nordson Corporation...
Страница 42: ...Specifications 7 2 Part 1074165A02 E 2010 Nordson Corporation System Drawing Figure 7 1 Lamphead Dimensions...
Страница 43: ...Specifications 7 3 Part 1074165A02 E 2010 Nordson Corporation Figure 7 1 Lamphead Dimensions...