Installation
3-3
Part 1074165A02
E
2010 Nordson Corporation
Light Shielding
S
Provide adequate shielding of UV light. The
lamphead must be enclosed such that no UV
light is allowed to escape.
S
Any louvered material used for exhausting must
be of a light-shielding design.
S
If UV light does escape the operator must wear
approved UV-protective eyewear and
long-sleeved clothing.
RF Detector
S
One RF detector is normally required for every
16 networked units within one curing enclosure.
However, some applications and systems may
require a RF detector on each unit. Contact
your Nordson representative for more
information.
S
Mount the RF detector so that the antenna
faces the lamphead screen and is between the
operator and the lampheads or the lampheads
and any opening (the major source for RF
leakage).
S
The minimum distance should be eight inches
to prevent excessive heat on the detector
surface.
S
Do not mount the RF detector directly below the
lamphead.
S
For RF detector connections, refer to
RF
Detector
in the power supply manual.
(3.50 in)
88.9 mm
(1.50 in)
38.1 mm
(0.50 in)
12.7 mm
(0.75 in)
19.1 mm
(Ø0.28 in)
Ø7.2 mm
(Ø0.16 in)
Ø4.0 mm
(0.55 in)
14.0 mm
(1.69 in)
42.8 mm
No RF Detector
12 in
8 in
Figure 3-2
RF Detector
Содержание Coolwave 610
Страница 4: ...Table of Contents ii Part 1074165A02 E 2010 Nordson Corporation...
Страница 12: ...Safety 1 8 Part 1074165A02 E 2010 Nordson Corporation...
Страница 22: ...Installation 3 6 Part 1074165A02 E 2010 Nordson Corporation...
Страница 34: ...Troubleshooting 5 2 Part 1074165A02 E 2010 Nordson Corporation...
Страница 40: ...Parts 6 6 Part 1074165A02 E 2010 Nordson Corporation...
Страница 42: ...Specifications 7 2 Part 1074165A02 E 2010 Nordson Corporation System Drawing Figure 7 1 Lamphead Dimensions...
Страница 43: ...Specifications 7 3 Part 1074165A02 E 2010 Nordson Corporation Figure 7 1 Lamphead Dimensions...