Maintenance and Repair
4-7
Part 1074165A02
E
2010 Nordson Corporation
NOTE:
Step six can be skipped if you are only
replacing the pressure switch.
6. Remove the transformer and connector bracket
by removing the three screws identified in
Figure 4-11 Transformer and Connector Bracket
Removal
7. See Figure 4-12. Pull the the transformer and
connector bracket from the lamphead base
Figure 4-12 Transformer and Connector Bracket
Pressure Switch
1. Follow steps 1
−
5 under
Internal Component
Replacement
lamphead cover.
2. Note the orientation of the pressure switch with
regard to the airflow direction.
3. See Figure 4-13. Remove the screws securing
the pressure switch to the insulating plate.
Figure 4-13 Pressure Switch Removal
Содержание Coolwave 610
Страница 4: ...Table of Contents ii Part 1074165A02 E 2010 Nordson Corporation...
Страница 12: ...Safety 1 8 Part 1074165A02 E 2010 Nordson Corporation...
Страница 22: ...Installation 3 6 Part 1074165A02 E 2010 Nordson Corporation...
Страница 34: ...Troubleshooting 5 2 Part 1074165A02 E 2010 Nordson Corporation...
Страница 40: ...Parts 6 6 Part 1074165A02 E 2010 Nordson Corporation...
Страница 42: ...Specifications 7 2 Part 1074165A02 E 2010 Nordson Corporation System Drawing Figure 7 1 Lamphead Dimensions...
Страница 43: ...Specifications 7 3 Part 1074165A02 E 2010 Nordson Corporation Figure 7 1 Lamphead Dimensions...