PROPlus / PRO Series Automated Dispensing Systems
80
www.nordsonefd.com [email protected]
+1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Method 2: Using Two Trig Marks (Faster)
PREREQUISITES
The system is in the CCD Mode.
Multiple workpieces are properly positioned on the fixture plate.
To Create Two Trig Marks
#
Click
Step
Reference Image
1
• Click CAMERA to go to the camera screen.
2
• Bring the image into focus. Refer to “Camera”
on page 17 as needed for instructions on
focusing the camera.
3
• Click LENS and make the SHUTTER setting
as low as possible while ensuring that you
can still clearly see the workpiece.
4
• Click CENTER to center the image of the
workpiece in the camera view.
Important:
The camera must be precisely
centered over the workpiece because the
offset values are calculated automatically.
5
• Click SET MARK, click and drag the
crosshairs of the red square over the first
target on the workpiece, then click and drag
the red square borders to position the square
around the target.
6
>
• Click a socket in the Mark Library to save
the mark, then click TEMPLATE when the
Template Match window appears.
7
• Repeat steps 5–6 to create a second mark on
the workpiece.
8
• Continue to “To Use Two Trig Marks in a Step
How to Use Trig Marks in a Step & Repeat Program (continued)