PROPlus / PRO Series Automated Dispensing Systems
49
www.nordsonefd.com [email protected]
+1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Robot Initial Setup (Step 2 Tab): Setting Up the Tip Detector (For Non-Laser Systems)
Important: If your system includes a laser, skip to “Robot Initial Setup (Step 3 Tab): Setting the Camera-to-Tip
#
Click
Step
Reference Image
1
• Click the STEP2 tab.
2
>
• Jog the tip until it is positioned about 2 mm
above the sensor on the tip detector.
• Click SET TIP DETECT POSITION.
3
• Click DETECT.
The tip touches the sensor to detect the
tip position and the system displays the tip
offset value next to the Detect button.
4
• Click DETECT again.
The system confirms the tip offset setting.
5
• Continue to “Robot Initial Setup (Step 3
Tab): Setting the Camera-to-Tip Offset” on
page 50.
Setting Up the System Using the Robot Initial Setup Wizard (continued)