(Laser Systems Only) Calibrating the Laser and Setting the Tip-to-Workpiece
Offset
#
Click
Step
Reference Image
1
>
• Click SYSTEM SETUP > OPEN.
2
• Under Tip Detect Device, enter a value of
10 (mm) for the Z Detect Limit.
3
ONLY SYSTEMS FOR NON-CONTACT
DISPENSING:
• As precisely as possible, center the jetting
orifice over the center of the sensor surface.
4
ONLY SYSTEMS FOR NON-CONTACT
DISPENSING:
• Click LASER DETECT SETUP and perform
steps 9 and 10 (skip steps 1 to 8). Close the
window after you have completed all the
steps.
NOTE:
To specify high or low Z height
limits for dispensing, check ENABLE LIMIT
FUNCTION and enter the desired values.
When this function is enabled, the system
prevents dispensing if the Z axis is above or
below the specified limits.
5
ONLY SYSTEMS FOR CONTACT
DISPENSING:
• Click LASER DETECT SETUP and follow the
steps in the Laser Detect Setup window.
Close the window after you have completed
all the steps.
NOTE:
To specify high or low Z height
limits for dispensing, check ENABLE LIMIT
FUNCTION and enter the desired values.
When this function is enabled, the system
prevents dispensing if the Z axis is above or
below the specified limits.
6
The system is now properly set up and
calibrated. Refer to “Programming” on
page 63 to create programs.