PROPlus / PRO Series Automated Dispensing Systems
81
www.nordsonefd.com [email protected]
+1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Method 2: Using Two Trig Marks (Faster) (continued)
To Use Two Trig Marks in a Step & Repeat Program
#
Click
Step
Reference Image
1
• Double-click a command address line and
select CAMERA TRIGGER.
NOTE:
The Camera Trigger command must
be near the top of the program.
2
• Click CENTER to center the image of the
workpiece in the camera view.
Important:
The camera must be precisely
centered over the workpiece because the
offset values are calculated automatically.
3
• Double-click a command address line and
select TRIG MARK.
The Trig mark command window opens.
• Enter the mark number (No.) of the first Trig
Mark in the No. field.
The system automatically populates the OX
and OY fields.
NOTE:
OX is offset X and OY is offset Y; the
system calculates the distance of OX and OY
as measured from the center of the workpiece
to the Trig Mark image.
4
• Repeat steps 2–3 for the second Trig Mark.
5
• Double-click a command address line, select
RECTANGLE ADJUST, and click OK.
NOTE:
Insert Trig Mark and Rectangle
Adjust commands near the beginning of the
program, after Camera Trigger and before any
dispense pattern commands.
After the program is complete, the secondary
view screen displays a yellow rectangle
around the desired workpiece orientation
defined by the Trig Marks.
Refer to the sample program provided on the
next page as a guideline.