Nordson EFD Product Safety Statement (continued)

Fire Safety

To prevent a fire or explosion, follow these instructions:

•  Shut down all equipment immediately if you notice static sparking or arcing. Do not restart the equipment until 

the cause has been identified and corrected.

•  Do not smoke, weld, grind, or use open flames where flammable materials are being used or stored.
•  Do not heat materials to temperatures above those recommended by the manufacturer. Make sure heat 

monitoring and limiting devices are working properly.

•  Provide adequate ventilation to prevent dangerous concentrations of volatile particles or vapors. Refer to local 

codes or the SDS for guidance.

•  Do not disconnect live electrical circuits when working with flammable materials. Shut off power at a disconnect 

switch first to prevent sparking.

•  Know where emergency stop buttons, shutoff valves, and fire extinguishers are located.

Preventive Maintenance

As part of maintaining continuous trouble-free use of this product, Nordson EFD recommends the following simple 
preventive maintenance checks:

•  Periodically inspect tube-to-fitting connections for proper fit. Secure as necessary.
•  Check tubing for cracks and contamination. Replace tubing as necessary.
•  Check all wiring connections for looseness. Tighten as necessary.
•  Clean: If a front panel requires cleaning, use a clean, soft, damp rag with a mild detergent cleaner. DO NOT USE 

strong solvents (MEK, acetone, THF, etc.) as they will damage the front panel material.

•  Maintain: Use only a clean, dry air supply to the unit. The equipment does not require any other regular 

maintenance.

•  Test: Verify the operation of features and the performance of equipment using the appropriate sections of this 

manual. Return faulty or defective units to Nordson EFD for replacement.

•  Use only replacement parts that are designed for use with the original equipment. Contact your Nordson EFD 

representative for information and advice.

Содержание Liquidyn V10D

Страница 1: ...Liquidyn V10D Controller Operating Manual Electronic pdf files of Nordson EFD manuals are also available at www nordsonefd com...

Страница 2: ...strial dispensing experience Most questions you will have are answered in this manual However if you need assistance please do not hesitate to contact EFD or your authorized EFD distributor Detailed c...

Страница 3: ...Equipment Specific Safety Information 10 Specifications 11 Operating Features 12 Front Panel Components 12 Rear Panel Components 12 Installation 13 Unpack the System Components 13 Install the Control...

Страница 4: ...is a highly accurate multi functional controller for use with Liquidyn micro dispensing valves The controller is capable of managing up to four different dispensing programs Program parameters can be...

Страница 5: ...f electric shock Disconnect power before removing covers and or disconnect lock out and tag switches before servicing electrical equipment If you receive even a slight electrical shock shut down all e...

Страница 6: ...vicing high pressure equipment A jet of high pressure fluid can cut like a knife and cause serious bodily injury amputation or death Fluids penetrating the skin can also cause toxic poisoning WARNING...

Страница 7: ...vice equipment unless you are qualified Do not operate equipment unless safety guards doors and covers are intact and automatic interlocks are operating properly Do not bypass or disarm any safety dev...

Страница 8: ...tch first to prevent sparking Know where emergency stop buttons shutoff valves and fire extinguishers are located Preventive Maintenance As part of maintaining continuous trouble free use of this prod...

Страница 9: ...lations after one time use Do not clean components with strong solvents MEK acetone THF etc Clean cartridge retainer systems and barrel loaders with mild detergents only To prevent fluid waste use Nor...

Страница 10: ...ct heat sources Fluid Compatibility Use only for the micro dispensing of high to low viscosity fluids or pastes Ensure that all fluid carrying parts and sealings are resistant to the dispensing materi...

Страница 11: ...ture 25 60 C 13 140 F Product classification IP40 Protection Class III Approvals CE RoHS WEEE China RoHS RoHS China RoHS Hazardous Material Declaration Part Name Toxic or Hazardous Substances and Elem...

Страница 12: ...e air power Valve connection for valve power USB to RS232 interface Port Description Power 7 pin socket from binder power supply connection Air Valve 3 pin M8 nozzle air power input cable connection J...

Страница 13: ...e worldwide 1 Liquidyn V10D controller 2 Power cord and power supply external power adapter 3 USB to RS 232 COM adapter cable and driver software 4 Push button board for testing Installation Use this...

Страница 14: ...s needed use the push button board to test the controller operation Refer to Use the Push Button Board to Test the Controller Operation on page 18 Setup NOTES The push button board can be used for tes...

Страница 15: ...hanges under the NEW VALUES column Refer to About the V10D Controller Parameters on page 16 for information about parameters 7 Click ENTER NEW VALUES to save the changes NOTE The controller can store...

Страница 16: ...Pulse Time 0 1 to 10 000 ms Corresponds to the electrical actuation time of the valve Must be adapted to the corresponding valve type jet type or dot type NOTE Refer to Pulse Time Setting for Jet Typ...

Страница 17: ...e valves corresponds to the opening time of the valve The dispensing volume can be adjusted by adjusting the Pulse Time Setup continued Pulse Time Setting for Dot Type Valves The Pulse Time must be 2...

Страница 18: ...programmed 7 START4 Runs Program 4 The valve dispenses as programmed Use the Push Button Board to Test the Controller Operation The V10D controller functions can be tested using the push button board...

Страница 19: ...V 3 75 Amp 7825175 Power cable banana plug 24V 2 m NOTE This cable can be used to connect power to the controller in place of the supplied power cord Note the pin assignments Red 24 VDC Black Mass Tro...

Страница 20: ...mote I O using the push button board Pin Direction Assignment Description 1 Output 24 VDC Out max 0 25 A Operating voltage 2 NC Not assigned 3 Input START1 Starts Program 1 4 Input STOP Stops 5 Input...

Страница 21: ...ldwide Power Supply Input Pin Assignments Pin Assignment Description 1 NC Not assigned 2 24 VDC Operating voltage 3 NC Not assigned 4 NC Not assigned 5 24V GND Operating voltage ground 6 NC Not assign...

Страница 22: ...m this warranty exceed the purchase price of the equipment This warranty is valid only when oil free clean dry filtered air is used Nordson EFD makes no warranty of merchantability or fitness for a pa...

Отзывы: