Liquidyn V10D Controller
20
www.nordsonefd.com [email protected]
800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
Technical Data
Input / Output Connector Pin Assignments
• All inputs and outputs are electrically separated.
• The controller is actuated by a 24V I/O signal at the Remote input. The
controller reacts to every square-shaped pulse (raising edge at least 2 ms.)
• Refer to "Use the Push-Button Board to Test the Controller Operation" on
page 18 to test the Remote I/O using the push-button board.
Pin
Direction Assignment
Description
1
Output
+24 VDC Out;
max. 0.25 A
Operating voltage
2
NC
Not assigned
3
Input
+ START1
Starts Program 1
4
Input
+ STOP
Stops
5
Input
+ SINGLE SHOT
Single shot mode, valve
6
Input
+ RESET
Counter / reset steps
7
Input
+ START2
Starts Program 2
8
Input
+ START3
Starts Program 3
9
Input
+ START4
Starts Program 4
10
Output
+ BUSY
Busy
11
Output
+ ERROR
Error notice (ON = No error)
12
Output
+ COUNTER
Counter
13
Output
- 24V (GND) Out
Operating voltage
14
NC
Not assigned
15
Input
- START1
16
Input
- STOP
17
Input
- SINGLE
18
Input
- RESET
19
Input
- START2
20
Input
- START3
21
Input
- START4
22
Output
- BUSY
23
Output
- ERROR
24
Output
- COUNTER
25
NC
Not assigned
14
25
1
13