Liquidyn V10D Controller
18
www.nordsonefd.com [email protected]
800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
Setup (continued)
Item
Push Button
Action
1
STOP
Stops the currently running sequence of steps /shots. Pushing the Start Button re-
starts the sequence of shots at the same position.
2
SINGLE SHOT
Dispenses individual shots (dots) from the valve.
3
RESET
Resets the currently running program to zero.
4
START1 (Start)
Runs Program 1. The valve dispenses as programmed.
5
START2 (Motor)
Runs Program 2. The valve dispenses as programmed.
6
START3 (DIR)
Runs Program 3. The valve dispenses as programmed.
7
START4 (---)
Runs Program 4. The valve dispenses as programmed.
Use the Push-Button Board to Test the
Controller Operation
The V10D controller functions can be tested using the push-button board.
NOTE:
For serial operation, or to incorporate the controller into a special
machine, I/O signals from a PLC can be connected to the Remote input,
instead of to the push-button board. For the Remote input pin assignment,
refer to "Input / Output Connector Pin Assignments" on page 20.
1. Connect the push-button board to the Remote input on the back of the
controller.
2. Press the buttons on the push-button board to test the controller
functions. Refer to the tables provided below.
3
2
1
5
4
7
6
LED
Indication
Description
BUSY
Illuminates
Controller running a
program
ERROR
Illuminates
Error
COUNTER
Flashes
Square-shaped pulse, 8
ms/shot