3. Safety distances
Firewall
Ensure that the minimum safety distances are fullfiled
(
FIG 1
).
When connecting a steel chimney to the top outlet use
the security distances required by the manufacturer.
Important! When placing the insert on
a combustible floor, a steel plate of at least
0.7mm must cover the entire floor surface inside
the surround. Any flooring made of combustible
material, such as linoleum, carpets etc. must be
removed from underneath the steel plate.
4. Assembly
Removing the insert from the pallet FIG 2
Before the insert is removed from the pallet, remove the
accessories in the combustion chamber.
Rear flue gas connection FIG 6
A chimney adapter is set in a rear chimney connection
position. If you want utilize rear chimney connection
remove a lid from rear shield by a suited tool.
Top flue gas connection FIG 6a
To utilize the top flue gas connection follow below steps:
1. Unscrew fastening bolts by provided tools.
2. Turn arround chimney adapter as shown on
the drawing.
3. Screw in the bolts to the body.
4. Place in the socket a rod stopping a chimney
sweeper ball.
Attention! Our inserts are prepared for connecting
the smoke pipe on the outside of the flue collar
Ø150.
*
Alternative versions of the flue collar exist due to
National requirements. For the flue connection to the
chimney, follow the recommendations from the chimney
manufacturer.
Operational control FIG 8
When the insert is in upright position, and prior to
mounting the surround, control that all functions are easy
to maneuver and appear satisfactory.
The insert expands when in use, and for
this reason the surround must NEVER rest
on the insert, but have a gap of about 3 mm.
The insert must neither rest on the bench plate or
against the sides. It is recommended to dry stack
the surround in order to adjust the insert prior
to perforating the chimney for the flue connection.
Technical TABLE
Insert
N-29A
Material
Steel
Surface treatment
Heat resistant varnish
/ Decorative chrome
Weight of insert (kg)
160 kg
Draught system
Ignition air vent control
and air vent control
Combustion system
Clean burning
Maximum fuel length (cm)
50
Flue outlet
Top and rear
Flue collar (Ø mm)
Outer 150
*alternate versions exists due to nationa requirements
Flue gas temperature at flue
connector (°C)
329
Draft at flue connector
recommended (Pa)
14-25
Data according to EN 13 229
Area of convection air vent under
insert (cm2)
500
Area of convection air vent over
insert (cm2)
700
Minimum distance conv. air outlet
to ceiling (mm)
500/750
Nominal heat output (kW)
8,9
Efficiency (%)
82
CO @ 13% O2 (%)
0,08
Flue gas temperature (°C)
269
Draft (Pa)
12
Fuel recommended:
Wood logs
Fuel length recommended (cm)
<50cm
Fuel charge (kg/)
2,2
Refueling interval (minutes)
45
Opening of the air vent
control (%)
30
Operation*
Intermittent*
* Intermittent combustion refers to normal use of a fireplace,
i.e. new wood is inserted when the previous load has burned
down to ember
Warning: If the requirements for ventilation are
NOT complied with, the cooling airflow around the
product will be considerably reduced and
the product can overheat.
This can cause a fire.
12
GB
Содержание IN-N29AL-010
Страница 54: ...FIG 4 Air inlet AIR AIR 3 mm FIG 3 Radiation shield assembling 54...
Страница 55: ...1 Door handle assembling 3 mm 2 FIG 5 a Wooden door handle assembling optional 1 3 mm 2 FIG 5 55...
Страница 56: ...FIG 6 Smoke adapter rear chimney connection FIG 6 a 180 Smoke adapter top chimney connection 2 3 4 5 1 10 mm 56...
Страница 58: ...FIG 9 Thermotte FIG 10 B C D B A B C E D F G H LA 0N29U 01L LA 0N29U 01R Thermotte assembling FIG 10 15 58...
Страница 59: ...FIG 11 FIG 12 LA 0N29U 02L LA 0N29U 02R 59...
Страница 60: ...FIG 13 LA 0N29U 040 LA N29AL 010 AL version AR version LA N29AR 010 FIG 14 60...
Страница 61: ...FIG 15 FIG 16 Rear chimney connection 22 0N29U 430 LA 0N29U 030 x1 1 3 2 5 mm 61...
Страница 62: ...22 0N29U 430 FIG 17 21 40009 013 x2 Max load size FIG 18 Radiation shield assembling 24 mm 62...
Страница 66: ...A A B C D E F G 2015 1186 kW ENERGIA ENERGIJA ENERGY ENERGIE A A A A A A Nordpeis AS Nordpeis N 29A U 8 9 66...
Страница 67: ...67...
Страница 68: ...Nordpeis AS Gjellebekkstubben 11 N 3420 LIERSKOGEN Norway www nordpeis no...