Regular servicing helps to maintain the operation of the humidifier.
The following work must be carried out by qualified personnel.

7.1 Regular checks

• Inspect the steam cylinder:
Are there any deposits in the steam cylinder?

⇒ 

Remove the drainage strainer and flush the cylinder thoroughly with tap water (without
chemical additives). Replace the strainer after cleaning.

Are the electrodes worn?

Replace the steam cylinder.

• Inspect all hoses (steam-, condensate- and water hoses), also inside the unit:

Is the installation correct?
Are all clamps still fastened tightly?

• Inspect the intake and drainage valves:

If worn or covered with scale deposits the valve must be replaced.

• Inspect the drainage cup.  Clean or replace if necessary.

7.2 Rectifying faults

The humidifier produces insufficient or no steam.  Following causes are possible:
• The humidity controller is not demanding any steam production.
• There is no water in the steam cylinder because the water supply is interrupted.
• The filter or the nozzle in the inlet valve is blocked or damaged.
• The cylinder is worn out and needs to be replaced.
• The contactor coil is defective.

7.3 Replacing the steam cylinder

The serviceable life of the steam cylinder depends on the actual operation time and the hardness of the tap water used.
The cylinder should be replaced when the system message “U1/cylinder service” appears on the LED display (flashing
green).  Under certain circumstances the cylinder can still be used before it has to be replaced.

Proceed as follows:
• Empty the cylinder by pressing the drainage-button

• Let the cylinder cool down

• For the following procedures the equipment must be disconnected from the power supply!

• Loosen the hose clamp on the head of the cylinder and then remove the steam hose.  Remove the electrode plugs

from the cylinder.  Push the cylinder up and remove it.

• Check the seal O-ring in the cylinder admission and replace if necessary.
• To fit the new cylinder reverse above procedure.
• Connect the heating cables to the electrode pins according to the coloured dots (for cylinders up to 3 electrodes)

respectively as shown in Fig. 7.1 (cylinders with 6 electrodes).

• Restart the humidifier according to section 6.1 (start-up).

7 Maintenance

!

Содержание 2401935EN0801

Страница 1: ...Operating Instructions Steam Humidifier 2401935 EN 0801 Nordmann econoVap NORDMANN E N G I N E E R I N G...

Страница 2: ...hat go beyond the scope of these operating instructions please contact the company from which you have purchased the humidifier or which has installed it As the manufacturers we are of course always r...

Страница 3: ...nt Attention Voltage This sign warns of dangerous electrical voltage Disregarding this warning can lead to danger or injury of the user NORDMANN humidifiers use ordinary tap water to produce steam The...

Страница 4: ...354 195 400 340 672 490 335 490 3 Installation Type Dimensions Fixing holes Steam outlet Drainage 4 8 kg h Fig 3 1 Fig 3 2 1 x 22 1 x 22 15 32 kg h Fig 3 3 Fig 3 4 1 x 35 1 x 22 45 65 kg h Fig 3 3 Fig...

Страница 5: ...the length of the steam hose should not exceed 1 5 meters A D C B 8 3 138 116 105 116 1 0 0 x 1 0 0 3 A C D M6 B 8 118 150 130 100 75 Type A mm B mm C mm D mm Fig Art no 22 300 300 22 176 60 3 6 902...

Страница 6: ...B A D E C G F B C A D E G F H J B C A D E G F H J A B D C E F G Type A B 4 8 kg 100 130 15 23 kg 180 240 Fig Type A B C D E F G mm mm mm mm mm mm mm 3 10 4 8 kg h 230 205 220 145 165 22 8 3 11 15 23 k...

Страница 7: ...in distance to other parts of the installation such as ventilators filters or pipe bends must be maintained The steam distribution pipes can be fitted either vertically or horizontally though it must...

Страница 8: ...For the humidifier to work best correct steam distribution is essential For this reason the minimum distances must be observed when installing the equipment Please note that only wall installation is...

Страница 9: ...m hose in pipes cable ducts etc their resi stance to high temperature min 100 C must be ensured All insulation material must also be checked for its resistance to high temperature If the steam line in...

Страница 10: ...tivity should be between 125 and max 1250 microSiemens per cm The hardness of water is measured in accordance with the international unit millimol calcium and magnesium ions per litre mmol l previousl...

Страница 11: ...qualified personnel only Before performing any electrical work all power to the humidifier must be disconnected Please observe local regulations concerning electrical installations The installation m...

Страница 12: ...ion phase The length of this phase can differ it lasts until the cylinder has reached the nominal rating When the Niveau max is attained it will be indicated by a red flash in the green colour of the...

Страница 13: ...to fill the cylinder continuously Either a heating phase or the water is missing The humidifier switches itself off automatically after 30 minutes After the fault has been rectified the unit is put b...

Страница 14: ...he inlet valve is blocked or damaged The cylinder is worn out and needs to be replaced The contactor coil is defective 7 3 Replacing the steam cylinder The serviceable life of the steam cylinder depen...

Страница 15: ...als can be processed by the adaptor Voltage 0 2 V 0 5 V 0 10 V 0 16 V 0 20 V SCS 1 5 V 2 10 V Current 0 20 mA 4 20 mA Potentiometer min 135 Ohm SC System The SC System is a patented self cleaning syst...

Страница 16: ...672 672 672 672 depth mm 210 210 210 210 340 340 340 340 340 Steam outlet diameter mm 1x22 1x22 1x22 1x22 1x35 1x35 1x35 2x35 2x35 Weight empty kg 11 5 11 5 12 12 20 21 22 5 24 24 Operating weight kg...

Отзывы: