9. Technical specifications
Other heating voltages on request.
Type mark:
Type
434
834
1534 2364 3264 4564 6564
Heating voltage
Volt
400 Volt, 50/60 Hz
Number of phases
~
3
3
3
3
3
3
3
Heating current
A
4.4
8.8
16.5 25.2 35.1 49.4
71.3
External fuses p. phase
A
10
16
25
40
50
80
100
Type mark:
Type
422 432 822 832 1532 2362 3262
Heating voltage
Volt
230 Volt, 50/60 Hz
Number of phases
~
1
3
1
3
3
3
3
Heating current
A
13.2
7.6
26.4
15.3 28.6 43.9 61.0
External fuses p. phase
A
20
16
40
25
40
63
100
Steam output
kg/h
4
4
8
8
15
23
32
45
65
Minimum capacity
kg/h steam
0.8
0.8
1.6
1.6
3
4.6
6.4
9
13
Nominal power
kW
3.0
3.0
6.1
6.1
11.4 17.5 24.3
34.2
49.4
Design data:
Dimensions
width mm
354 354 354 354 490 490 490
490
490
height mm
562
562
562 562 672 672 672 672
672
depth mm
210
210
210
210 340 340 340 340 340
Steam outlet diameter
mm
1x22
1x22
1x22
1x22
1x35
1x35
1x35
2x35
2x35
Weight (empty)
kg
11.5
11.5
12
12
20
21
22.5
24
24
Operating weight
kg
15
15
18.5
18.5
35
36
47.5
49
49
Accessories:
Humidity controller
qty
1
1
1
1
1
1
1
1
1
Control electronics:
Supply voltage
Volt
220–240 Volt, 50/60 Hz, 1~
Proportional adaptor
qty
1
1
1
1
1
1
1
1
1
Steam distributors for dct use:
Steam nozzle
qty
1
1
22-xxx mm
qtv
1
1
1
1
35-300 mm
qty
1
35-450 mm
qty
1
1
2
35-600, 35-900 mm
qty
1
1
1
2
2
35-1200, 35-1500 mm
Steam hose:
Ø
22/29 mm
qty x m
1
1
1
1
Ø
35/43 mm
qty x m
1
1
1
2
2
Condensate hose:
Ø
6/10 mm
qty x m
1
1
1
1
1
1
1
2
2
Steam blowers for direct room humidification
Split mounted
qty
1
1
1
1
1
1
1
1
1
Manufacturer:
Walter Meier (Climate international) ltd.
talstr. 35-37, P.O. Box, CH-8808 Pfäffikon (switzerland)
Phone +41 55 416 61 11, Fax +41 55 416 62 62
[email protected] / www.nordmann-engineering.com