Configuration procedure for Rasul application:
1. Reset SPA Control to factory settings.
(Path: Engineering > SPA Control Board > Factory Reset)
2.
Important
: This step must be carried out only with single cabin application:
Reset SPA Display to factory settings.
(Path: Engineering > Admin > Display > Factory Reset)
3. Set cabin type to "
Rasul
".
(Path: Engineering > SPA Control Board > Cabin Kind > Rasul)
4. Set the treatment mode for Rasul operation ("Off" or "Keep Warm")
(Path: Engineering > Control Settings > Treatment Mode)
Note
: Further notes on the treatment mode can be found in
5. Determine humidity control settings:
(Path: Engineering > Control Settings > Humidity Control)
• Determine the humidity sensor signal type ("0 - 5V", "1 - 5V", "0 - 10V", "2 - 10V", "0 - 20V",
"0 - 16V", "3 - 16V", "0 - 20mA", "4 - 20mA" or "On/Off")
6. Determine accessory control:
(Path: Engineering > Accessories)
• Determine the control of Light 1 and Light 2
• Determine the control of fragrance pump 1 (Aroma 1) and shower valve (Aroma 2)
• Determine the fan control (for single stage fans 1 and 2 or three-stage fan 1)
• Determine the control of relay 8 and 9 (Path: Engineering > Accessories > Outputs)
– "Relay 8 Mode": Set to "Bench Heater" to activate the bench heating
– "Relay 8 Mode": Set to "Wall Heater" to activate the wall heating
7. Determine temperature control settings for the bench heating:
(Path: Engineering > Control Settings > Bench Temp. Control)
• Select temperature sensor type ("PT100", "PT1000 (0.1mA)", "PT1000 (1.0mA)", "KTY (1.0mA)")
• Set the critical temperature in °C/°F above which a warning appears.
8 Determine temperature control settings for the wall heating:
(Path: Engineering > Control Settings > Wall Temp. Control)
• Select temperature sensor type ("PT100", "PT1000 (0.1mA)", "PT1000 (1.0mA)", "KTY (1.0mA)")
• Set the critical temperature in °C/°F above which a warning appears.
9. Determine unit size.
(Path: Engineering > Steam Generator > Tank Settings > Capacity)
Note
: The unit size can be found on the rating plate of the Nordmann Omega under steam output.
10. Determine supply water type and cartridge size:
• Determine the supply water type ("Tap Water", "RO" or "Filter Cartridge") and the carbonate
hardness of the supply water (only if water supply type is set to " Tap Water" or "Filter Cartridge")
(Path: Service > Steam Generator > Water Supply > Type)
• Determine cartridge size (only if water supply type is set to "Filter Cartridge")
(Path: Service > Steam Generator > Filter Cartridge > Cartridge Size)
11. Set current date and time of day:
(Path: User > General)
• Set date
• Set time of day
Содержание Omega 12