58
Modbus Settings
Setting the Modbus parameters.
– Protocessor:
– Slave Address: Determining the slave address of the Protocessor.
– Baudrate: Determining of the baud rate (4800, 9600, 19200, 38400, 57600, 115200)
– Parity: Determining of the parity (none, 1 stop bit; none, 2 stop bit; odd, 1 stop bit;
even, 1 stop bit)
– Data Format: Determining of the byte order (ABCD: big edian; BADC: big, swap;
CDAB: little, swap; DCBA: little, endi.)
– Gateway:
– Slave Address: Determining the slave address of the Gateway.
– Baudrate: Determining of the baud rate (4800, 9600, 19200, 38400, 57600, 115200)
– Parity: Determining of the parity (none, 1 stop bit; none, 2 stop bit; odd, 1 stop bit;
even, 1 stop bit)
– Data Format: Determining of the byte order (ABCD: big edian; BADC: big, swap;
CDAB: little, swap; DCBA: little, endi.)
Note
: Detailed notes on Modbus communication can be found in the Modbus addendum manual.
Factory Reset
Resetting Omega Control Board settings to factory defaults.
File System Reset
Resetting the internal file system.
Note: The file system must be reset only if it does not function correctly anymore. Resetting
the file system may take several minutes (up to 5 minutes). Leave the device switched on and
wait until everything is working properly again.
Steam Generator
Note
: This menu only appears only for steam shower application, steam bath application, Caldarium application, Rasul applica-
tion and Bio Sauna application, if the steam generator type is set to "Internal Omega", "Internal Reservoir", "External Omega"
or "External Analog"
Steaming Settings
Determining of the steam settings for the steam generator
– Control Source: If only one control board is available, the control is local ("Local"). If the
steam generator is controlled by an external SPA Control Board, it is necessary to switch
to remote control ("Remote"). In the case of a remote control, the server ID of the SPA
Control Board must be specified under "Control Server ID".
– Input signal: Determining of the type of demand signal for the steam generator
(0-5V, 1-5V, 0-10V, 2-10V, 0-20V, 0-16V, 3-16V, 0-20mA, 4-20mA, On/Off).
– Control Server ID: Server ID of the control board that controls the steam generator.
– Steam Demand: Current steam demand to the steam generator in %.
Generator
Shows the currently produced steam quantity by the steam generator in %.
Level
Current water level in the water tank.
Tank Settings
Settings of the water tank.
– Capacity: Setting the device size 4 kg/h, 8 kg/h, 12 kg/h, 16 kg/h or 20 kg/h.
– Size: The water tank size is automatically determined by the capacity.
Reservoir Settings
Settings of the water reservoir for a Bio sauna heater.
–
Capacity: Determining of the size of the water reservoir integrated in the Bio sauna heater.
Safety
Status indications of the safety elements of the steam generator.
– Tank Overtemp.: Status display of the overtemperature sensor on the water tank.
–
Low Water: Status indication of the low water level sensor in the integrated water reservoir
of the Bio sauna heater.
Admin
Password
Determining a password for the user level (no password set ex factory).
Display
Determining of the settings for the SPA Display Software.
– Server ID Display: Setting the server ID of the SPA display.
– Calibrate: Performing a calibration of the SPA display.
– Factory Reset: Resetting the display electronic settings to factory defaults.
– File System Reset: Resetting the internal file system.
Note: The file system of the SPA display must be reset only if a logo must be reset or if
the file system does not function correctly anymore. Resetting the file system may take
several minutes (up to 5 minutes). During resetting, it may be that the SPA display is not
working properly and the SPA display turns white. In this case, leave the device switched
on and wait (max. 5 minutes) until everything is working properly again.
System Parameters
Determining of the settings for importing and exporting data and recording logger data.
– Export: Export of data to the internal file system ("SpaExportSettings.json").
– Import: Import of data from the internal file system ("SpaExportSettings.json").
–
Logger: Activation ("On") or deactivation ("Off") of logger data recording (SpaLogEvent_DA-
TUM.json).