33
Configuration procedure for steam shower application with temperature controlled or constant
steam production:
1. Reset SPA Control to factory settings.
(Path: Engineering > SPA Control Board > Factory Reset)
2.
Important
: This step must be carried out only with single cabin application:
Reset SPA Display to factory settings.
(Path: Engineering > Admin > Display > Factory Reset)
3. Determine temperature control settings (for temperature controlled steam shower application only):
(Path: Engineering > Control Settings > Temperature Control)
• Select temperature sensor type ("PT100", "PT1000 (0.1mA)", "PT1000 (1.0mA)", "KTY (1.0mA)")
• Set the critical temperature in °C/°F above which a warning appears
4. Determine unit size.
(Path: Engineering > Steam Generator > Tank Settings > Capacity)
Note
: The unit size can be found on the rating plate of the Nordmann Omega under steam output.
5. Determine supply water type and cartridge size:
• Determine the supply water type ("Tap Water", "RO" or "Filter Cartridge") and the carbonate
hardness of the supply water (only if water supply type is set to " Tap Water" or "Filter Cartridge")
(Path: Service > Steam Generator > Water Supply > Type)
• Determine cartridge size (only if water supply type is set to "Filter Cartridge")
(Path: Service > Steam Generator > Filter Cartridge > Cartridge Size)
6. Set current date and time of day:
(Path: User > General)
• Set date
• Set time of day