Cast iron fireplaces
Instructions for installation, use and maintenance – EN – Rev.07
27
8. CONNECTION AND MAINTENANCE OF VENTILATION
I Our fireplaces are equipped with appropriate galvanized coverings (OPTIONAL) on which it is possible to
install the ventilation kits (OPTIONAL) suitable to improve the distribution of heat through the ventilation
exclusively in the installation room or in the adjacent local (see CAP. 6).
The lighting and the adjustment is carried out through the proper standard supplied control unit that has to
be installed far from any direct heat source. The kit is equipped with a thermostat (TM) that lets the fans
start when the appliance is properly heated, and stops them when it is partially cold.
CONNECTION:
Connect the power supply cable of the control unit to a bipolar switch equipped with fuses (power supply
230 V ac 50 Hz, it is necessary to provide for the correct connection to the grounding plant).
The control unit and the plant must be installed and connected by authorized personnel according
to the standards in force. (see chapter.1).
WARNING:
The COMMAND must be connected to the mains with a
differential line cut-off switch according to the regulations
in force. Correct operation of the command is assured only
for the proper motor for which it has been manufactured.
Improper use relieves the manufacturer from each
responsibility.
Figura 16
Figure 17
(TM)
(7)
Fire-retardant counter-hood
(9)
Shield wooden parts with
insulating material
(8)
Maximum inclination
45°
(2)
Seal
(3)
Insulating coating with external
aluminum sheet
(4)
Door for cleaning
(5)
External air intake
(1)
Insulating material
(6)
Heat drain grating
(10) Rear and side distances
Min. 10 cm