28
Note: The toggle switch must be in the NORMAL position for the
normal functions of the system to operate.
6.2 Setting Units
Note: To change units, the Weights and Measures seal will have to be
broken. Contact NORAC prior to breaking the seal or have a qualified scale
dealer break the seal. Breaking the seal may violate the Weights and
Measures approval of the scale.
NOTE: If you attempt to change the units through the indicator, the Weigh
Center will automatically switch the units back to the DIP switch setting (see
below).
1. Open the faceplate where the indicator is mounted. To open the faceplate,
remove the two screws at the top of the panel and fold it forward (see
Error!
Reference source not found.
).
2. Inside the control panel there is a circuit board with a small bank of
switches (DIP switches). These DIP switches are located on the front corner
of the circuit board. As shown in the diagram below, the side of the DIP
switch that is down determines if the switch is in the open or closed position.
3. The units can be in kilograms (kgs) or pounds (lbs). To change this
setting find switch #7 and set appropriately.
Closed = kgs
Open = lbs
6.3 SETTING SYSTEM ID NUMBER
Supply 14 Volts potential to the circuit board through the Truck Cable. Power
up the M2000.
Open DIP-switch 3 on the circuit board.
Key in 20 <SELECT> and enter in the last three digits of the indicator serial
number, e.g. S/N S0750 key in 750, and press <SELECT>.
Close DIP-switch 3.
Содержание M2000
Страница 24: ...20 Standard Load Cell Numbering Cell and Trimmer locations Multiple Animal Scales ...
Страница 25: ...21 Standard Load Cell Numbering Cell and Trimmer loactions Onboard Scales ...
Страница 30: ...26 Cab Alarm Wiring OnBoard Applications Scale Up Alarm Magnetic Reed Switch Wiring OnBoard Applications ...