18
EXAMPLE: OB30L-F3 System
Balancing Weights: English = 5000 lb.
Metric = 2000 KG
Graduations:
English = 5 lb.
Metric = 2 KG
First Loading
English Units (lbs.)
Cell
Metric Units (kg)
M2000 Reading
M2000 Reading
Start Loaded Unloaded
Start Loaded Unloaded
0 4995 0
1 0 1998 0
0 4990 0
2 0 1996 0
0 5005 0
3 0 2002 0
From the above results, it can be seen that cells 1 and 3 must be adjusted
down to read 4990 lbs. (1996 kg in the metric example). First, the trimmer
for cell 1 is turned clockwise to bring the reading down (step 6(c)).
Second Loading
English Units (lbs.)
Cell
Metric Units (kg)
M2000 Reading
M2000 Reading
Start Loaded Unloaded
Start Loaded Unloaded
0 4990 0
1 0 1996 0
2
3
Next, the trimmer for cell 3 is turned clockwise to bring its reading down.
Because this cell is being adjusted by three graduations, the procedure in
6(d) should be followed, adjust cell 3 down to 4985 lbs. (1994 kg in the
metric example) and check for a zero shift.
Third Loading
English Units (lbs.)
Cell
Metric Units (kg)
M2000 Reading
M2000 Reading
Start Loaded Unloaded
Start Loaded Unloaded
1
2
0 4985 -5
3 0 1994 -2
Содержание M2000
Страница 24: ...20 Standard Load Cell Numbering Cell and Trimmer locations Multiple Animal Scales ...
Страница 25: ...21 Standard Load Cell Numbering Cell and Trimmer loactions Onboard Scales ...
Страница 30: ...26 Cab Alarm Wiring OnBoard Applications Scale Up Alarm Magnetic Reed Switch Wiring OnBoard Applications ...