27
6.1 Setting Time and Date
Inside the control panel, in the ceiling of the printer compartment you will find
two toggle switches near the back (See
Error! Reference source not found.
).
The right toggle switch is a two-position switch (Program switch) that puts the
indicator PROGRAM TIME AND DATE or NORMAL modes. Pull the
program switch ahead to put the system into indicator PROGRAM TIME
AND DATE mode. Push the switch toward the back of the box to resume
NORMAL operation.
1.
Pull the program switch into the PROGRAM TIME AND DATE position
as described above.
2.
Place a piece of paper into the printer.
3.
Enter the desired date into the indicator set point register in a DDMMYY
(Day Month Year) format using the key sequence outlined below. For
example June 16, 2002 would be entered as:
[
2
][
0
] [
PRINT/SELECT
]
[
1
][
6
][
0
][
6
][
0
][
2
] [
PRINT/SELECT
]
Note: You have a limited amount of time to enter the actual date
keystrokes (about 4 seconds). If the indicator goes back to
GROSS
mode
before you get the entire date entered you must type
[
2
][
0
][
PRINT/SELECT
] again then enter the date keystrokes.
4.
Hold the [
START
] button until your keystrokes start to be displayed,
about 5 seconds, then release. The indicator will automatically repeat your
keystrokes and the printer will output the following message:
Enter date please:
date received, start to continue
5.
Enter the desired time into the indicator set point register in HHMM
(Hours Minutes) format using the key sequence outlined below. The time
must be in a 24-hour format. For example 1:15 PM (13:15) would be
enter as:
[
2
][
0
] [
PRINT/SELECT
]
[
1
][
3
][
1
][
5
] [
PRINT/SELECT
]
Note: You have a limited amount of time to enter the actual time
keystrokes (about 4 seconds). If the indicator goes back to
GROSS
mode
before you get the entire date entered you must type
[
2
][
0
][
PRINT/SELECT
] again then enter the date keystrokes.
6.
Press the [
START
] button briefly once. The indicator will automatically
repeat your keystrokes and the printer will output the following message:
time received, start to continue
7.
Press the [
START
] button briefly once again. The printer will output the
following message:
1606021315 rec’d
8.
Push the program switch back into NORMAL position.
9.
End of procedure.
Содержание M2000
Страница 24: ...20 Standard Load Cell Numbering Cell and Trimmer locations Multiple Animal Scales ...
Страница 25: ...21 Standard Load Cell Numbering Cell and Trimmer loactions Onboard Scales ...
Страница 30: ...26 Cab Alarm Wiring OnBoard Applications Scale Up Alarm Magnetic Reed Switch Wiring OnBoard Applications ...