26
Figure 32 – Cable Configurations: C01, C10 and C04
2.
On the right-hand side of the cab there is
an electrical access panel. The tee
connection on the UC4+ power cable
(
C10
) must be connected between the 9-
pin connector shown in
Figure 33
and
the electrical panel.
3.
The free-hanging yellow wire from
C10
must be electrically connected to the
light blue bypass wire in the main wire
harness that exits the rear of the access
panel (
Figure 33
). Use a multimeter to
ensure you have selected the right wire.
The light blue wire should have
12-Volts on it whenever one of the
boom LIFT switches is operated.
Use a tee electrical connector as
shown (not provided) or solder
and seal appropriately.
Figure 33 - UC4+ Power Cable Connection
Bypass Valve
Connection
Tee Connection