17
4.6.2 Chassis Roll Sensor Mounting
1.
It is often best to cable tie the chassis roll
sensor in place. When mounting the chassis
roll sensor follow the guidelines and refer to
Figure 18
.
The chassis roll sensor must be
mounted on a portion of the sprayer
that does not pivot and is as close to
the boom frame roll sensor as possible
(Figure 16).
a)
Make sure you are using the roll sensor
with the temperature probe (
E03
).
b)
Ensure the roll sensor is level with
respect to the chassis.
c)
The AMP (circular) connector
MUST
exit towards the right hand wing
.
d)
Make sure the temperature probe is able
to reach the side of the valve block.
Figure 18 – Chassis Roll Sensor Mounting
2.
Fasten the temperature probe to the UC4+
valve block, using the supplied 3/8”x1/2”
bolt as shown in
Figure 19
.
3.
Cable-tie the temperature probe cable and
AMP (circular) connector securely to a frame
member.
Check that the roll sensors and cables
will not interfere with, or come into
contact with any parts of the sprayer.
Figure 19 – Temperature Probe Attached to
the UC4+ Valve Block
Содержание Gregson Maverick 120 Series
Страница 9: ...7 Figure 3 Hydraulic Components ...
Страница 14: ...12 Figure 9 Sensor Serial Number Installation Location 3 SENSOR SYSTEM 5 SENSOR SYSTEM ...
Страница 32: ...30 5 3 ITEM C02B 44664 CABLE UC4 CAN NODE DUAL 5 4 ITEM C03 44656 VALVE CABLE VARIABLE RATE ...
Страница 33: ...31 5 5 ITEM C04 44651 VALVE EXTENSION CABLE ...
Страница 34: ...32 5 6 ITEM C10 44650 11 POWER CABLE GREGSON MAVERICK ...