background image

2

Slow down

Working times learning

Eletrical adjust of the force of the motor

4 functions (apartment block included).

Functions set up throught a dip

Free contact for light indicating the open gate

Radio included which can manage codes rolling.

Small dimensions

Pedestrian door (partial opening) with separate command

Electrical lock and selecting reversing stroke

Dip esclusione di tutti gli ingressi di sicurezza.

Inputs exclusion limit switches with a DIP

The START S4XL control board is designed to move gates. It can be 

connected to an oleodinamic motor or electro-mechanical motor with a

single-phase motor, in 230 Vac.

1.2  Field of application

1.1  Description of the product

Making the correct choice of installation is essential to ensuring adequate

safety and good protection against atmospheric agents. Remember that 

the control unit contains powered parts and electronic components which 

by their very nature are sensitive to infi ltrations and moisture. The control 

unit is supplied in a container which guarantees an IP55 protection rating 

if adequately installed. Install the control unit on a permanent surface that 

is perfectly fl at, adequately protected against impacts and at least 40 cm 

off the ground. The cables must enter the control unit from the bottom 

only; we recommend using wire leads and water-tight connections.

When using tubing that could fi ll up with water or if the tubing comes from

an underground well, the wires must enter a fi rst shunting box placed at

the same height as the control unit and then, from there, the wires must

be passed into the container holding the control unit, again entering from

the bottom. This prevents any evaporation of the water in the tubing from

forming condensation inside the control unit itself.

2.1  Preliminary checks

Remember that systems for automatic gates and doors must be installed 

by highly qualifi ed technicians only and in full compliance with current 

law. Before starting installation, check that the mechanical consistency 

and sturdiness of the gate or door, check that the mechanical stops are 

suitable to stop the movement of the gate or door even if the electrical 

limit switches should fail or during manual operations.

2 Installation

1 Introduction

START-S4XL is the ongoing evolution of the START-S4 electronic control

unit, completely compatible and equipped with a sophisticated electronic

circuit that controls the motive force, detecting any obstacles at any point

in its operation.

The design has adapted the most advanced techniques to guarantee 

utmost immunity vs. noise, maximum operating flexibility and to make a

wide choice of functions available.

 Foreword

This manual provides all the specific information you need to fa

-

miliarize yourself with and correctly operate your unit. Read it 

very carefully when you purchase the instrument and consult it 

whenever you have doubts regarding use and before performing 

any maintenance operations.

 

Safety precautions

Using the unit improperly and performing repairs or modifications

personally will void the warranty.

Nologo declines any responsibility for damages due to inappro-

priate use of the product and due to any use other than the use 

the product was designed for. 

Nologo declines any responsibility for consequential damages 

except civil liability for the products.

 

Environmental protection

 measures

Information regarding the environment for customers 

within the European Union. European Directive EC 

2002/96 requires that units bearing this symbol on the 

unit and/or on the packaging be disposed of separate-

ly from undifferentiated urban wastes.  The symbol in-

dicates that the product must not be disposed of with

the ormal household wastes. The owner is responsible for dis-

posing of this product and other electrical and electronic equip-

ment through specific waste collection facilities indicated by the 

government or local public agencies. Correct disposal and recy-

cling help prevent any potentially negative impact on the environ-

ment and human health. To receive more detailed information 

regarding disposal of your unit, we recommend that you contact 

the competent public agencies, the waste collection service or 

the shop where you purchased the product.

 

Small legend

LSO - FCA

limit switch open

LSC - FCC

limit switch closed

START

control to drive the gate

PEDESTRIAN

in sliding units: control partial opening

Vac

alternate current

Vdc

direct current

NC

normally closed

NA

normally open

Isolated contact

isolated from power supply

Содержание START-S4XL

Страница 1: ...230 Vac Lamp Motor 1 COMMON Motor 1 OPEN Motor 1 CLOSE Motor 2 COMMON Motor 2 OPEN Motor 2 CLOSE Open Limit Switch Mot 2 Clos Limit Switch Mot 1 Closing photocell Start Button 24Vac 24 Vac 12Vac elec...

Страница 2: ...ical limit switches should fail or during manual operations 2 Installation 1 Introduction START S4XL is the ongoing evolution of the START S4 electronic control unit completely compatible and equipped...

Страница 3: ...75 mm2 Use shielded cables if the length exceeds 30m and connecting the ground braid only from the side of the control unit Do not connect the cables in underground cases even if they are water tight...

Страница 4: ...OPEN M2 M 2 Closing 11 Output to connect motor no 2 pole CLOSE FCC M2 12 Input Closing limit switches motor no 2 FCA M2 13 Input Opening Limit Switches 2 FCC M1 14 Input for Closing limit switches of...

Страница 5: ...and if adjusted at the maximum power the door opens when the second door has finished the working time In next opening will the new value valid 0 Max SPEED SLOW DOWN Setting up of the speed of the sl...

Страница 6: ...8 9 10 1 2 7 3 ON REVERSING STROKE This function starts a closing thrust at the beginning or at the end of the manoueuvre to make easy the work of the electrical lock 4 ON Courtesy light In the output...

Страница 7: ...pening displacement will be at 2 seconds The closing displacement can be chosen with the trimmer displacement 7 X Leave in the OFF 8 OFF Time learning planned from the user Leave in OFF when used the...

Страница 8: ...put photocell always activated 8 ON Radio DECODE It activate the radio receiver 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 8 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7...

Страница 9: ...ry all codes is possible only when the gate is closed 1 Make sure that the gate is in closed position 2 Push the codes button until the L E D CODICE flashes AND release it Wait until the reset of the...

Страница 10: ...nt time the first motor closes 5 Press the TIMES button or START if the limit switches are not available The second motor stops wait until the first motor stops END OF LEARNING TIME if the limit switc...

Страница 11: ...switch of motor no 2 is not available The second motor stops the first motor CLOSES 9 a if the limit switch is available wait until motor no 2 stops The motor no 2 stops motor no 1 closes 10 Push the...

Страница 12: ...ls for the TEST function Now the control unit check the TEST function of all devices and the the gate opens with a little bit delayed 8 6 9 10 7 8 Make all connections to the TEST as shown in the manu...