background image

1  

  3

230 Vac control board power supply

4   

 11

230 Vac motors power supply and 230Vac lamp

12  

  18

Accessories power supply and services and securities inputs

19  

  20

Output for 12 Vac 50 Hz 1 A electrical lock, is powered for 3 seconds only by opening

21  

  25

Commands, safeties, antenna

26  

  27

Free contact for light indicating open gate or lamp without flashing card.

28  

  31

Fototest and accessories tension and inputs for services and safeties.

TIMES

button for working time learning and setting up of “ VELOCE ”( fast) of the pause –time. For

PEDESTRIAN ( partial opening ) learning time keep pressed till the opening of the MOTOR 1

CODES

button to memorize the codes in the receiver( cancellation of the memory and codes learning)

FORCE

MOTOR FORCE ADJUST

20% TO 100%

PhASE-DIS.

Setting up of the TIME PHASE DISPLACEMENT DOORS by opening and closing: Departing minimum

speed of 1 sec and , if adjusted at the maximum power, the door opens when the second door has

finished the working time. In next opening will the new value valid (0 Max).

SPEED

SLOW

DOWN

Setting up of the speed of the slow down and remove of the slow down. (MINIMUM _OFF). For the most

part of the motors set up the speed at about 1/3 of the normal speed of the motor. TO remove the slow

down, turn the trimmer in OFF.

LED

OPENING

Signal lamp to indicate the status of the automation (see diagram)

LED 

CLOSING
LED CODES

2.6  Connections and setting up

5

OPEN

CLOSE

CODES

The led for codes flashes:

The gate is closed

led indicating the opening

is switching on:

The gate is opening

led in opening flashes:

The gate is in opening

slow down

led by closing is switched 

on:

 The gate is closing

led in closing flashes:

The gate is slowing down by

closing

led opening and closing flashes:

The gate is open and stop

led opening and closing and l.e.d. codes 

flashes:

Fast setting up of the pause time

OPEN

CLOSE

CODES

OPEN

CLOSE

CODES

OPEN

CLOSE

CODES

OPEN

CLOSE

CODES

OPEN

CLOSE

CODES

OPEN

CLOSE

CODES

Содержание START-S4XL

Страница 1: ...230 Vac Lamp Motor 1 COMMON Motor 1 OPEN Motor 1 CLOSE Motor 2 COMMON Motor 2 OPEN Motor 2 CLOSE Open Limit Switch Mot 2 Clos Limit Switch Mot 1 Closing photocell Start Button 24Vac 24 Vac 12Vac elec...

Страница 2: ...ical limit switches should fail or during manual operations 2 Installation 1 Introduction START S4XL is the ongoing evolution of the START S4 electronic control unit completely compatible and equipped...

Страница 3: ...75 mm2 Use shielded cables if the length exceeds 30m and connecting the ground braid only from the side of the control unit Do not connect the cables in underground cases even if they are water tight...

Страница 4: ...OPEN M2 M 2 Closing 11 Output to connect motor no 2 pole CLOSE FCC M2 12 Input Closing limit switches motor no 2 FCA M2 13 Input Opening Limit Switches 2 FCC M1 14 Input for Closing limit switches of...

Страница 5: ...and if adjusted at the maximum power the door opens when the second door has finished the working time In next opening will the new value valid 0 Max SPEED SLOW DOWN Setting up of the speed of the sl...

Страница 6: ...8 9 10 1 2 7 3 ON REVERSING STROKE This function starts a closing thrust at the beginning or at the end of the manoueuvre to make easy the work of the electrical lock 4 ON Courtesy light In the output...

Страница 7: ...pening displacement will be at 2 seconds The closing displacement can be chosen with the trimmer displacement 7 X Leave in the OFF 8 OFF Time learning planned from the user Leave in OFF when used the...

Страница 8: ...put photocell always activated 8 ON Radio DECODE It activate the radio receiver 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 8 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7...

Страница 9: ...ry all codes is possible only when the gate is closed 1 Make sure that the gate is in closed position 2 Push the codes button until the L E D CODICE flashes AND release it Wait until the reset of the...

Страница 10: ...nt time the first motor closes 5 Press the TIMES button or START if the limit switches are not available The second motor stops wait until the first motor stops END OF LEARNING TIME if the limit switc...

Страница 11: ...switch of motor no 2 is not available The second motor stops the first motor CLOSES 9 a if the limit switch is available wait until motor no 2 stops The motor no 2 stops motor no 1 closes 10 Push the...

Страница 12: ...ls for the TEST function Now the control unit check the TEST function of all devices and the the gate opens with a little bit delayed 8 6 9 10 7 8 Make all connections to the TEST as shown in the manu...

Страница 13: ...989 harmonizing the legislation of the member countries regarding electromagnetic compatibility Reference to harmonized standards EN 61000 6 2 EN 61000 6 3 THE PRODUCT COMPLIES with the essential requ...

Страница 14: ...sous la seule responsabili du constructeur et si applica ble de son repr sentant autoris Busto Arsizio Va Italia 14 06 2007 ERNESTINO BANDERA Administrateur KONFORMIT TSZERTIFIKAT Der Unterzeichner be...

Отзывы: