background image

13

Declaration of CE conformity

(according to EC Directive 98/37, Attachment II, part B)

The undersigned Ernestino Bandera,

Administrator

DECLARES ThAT:

Dairago, 14 giugno 2007 

 

The Administrator

Ernestino Bandera

ThE PRODUCT COMPLIES

with what is outlined in the European Community directive:

EC 98/37 (EEC 89/392 modified)

EC DIRECTIVE 98/37 ISSUED BY THE EUROPEAN PARLIAMENT AND  COUNCIL 

on June 22, 1998 harmonizing the legislation of the member countries regarding 

machinery.

Reference: Attachment II, part B (EC Declaration of Conformity issued by the manufacturer).

ThE PRODUCT COMPLIES

with what is outlined in the following European Community

directives, as modified by EEC Directive 93/68 issued by the

EUROPEAN COUNCIL on July 22, 1993

73/23/CEE 

with what is outlined in the following European Community directives, as modified 

by EEC Directive 93/68 issued by the EUROPEAN COUNCIL on July 22, 1993 

Reference to harmonized standards: EN 60335-1

89/336/CEE 

EEC DIRECTIVE 89/336 ISSUED BY THE EUROPEAN COUNCIL on May 3, 1989,

harmonizing the legislation of the member countries regarding electromagnetic 

compatibility

Reference to harmonized standards: EN 61000-6-2 EN 61000-6-3

ThE PRODUCT COMPLIES

with the essential requirements of article 3 of the following 

European Community Directive, for the use for which the 

product is designed:

1999/5/CE 

EC DIRECTIVE 1999/5 ISSUED BY THE EUROPEAN PARLIAMENT AND 

COUNCIL on March 9, 1999 regarding wireless units and telecommunications 

terminals and their reciprocal recognition

Rifering to the standars norms: ETSI EN 300 220-3 ETSI EN 301 489-1 ETSI EN 301 498-3

The directive 98/37/Ce remind that it is not allowed the function of the product until the machine, for which

the product is included, is not indentify and declared conformed to the 98/37/ce directive.

Company: 

 

EB TEChNOLOGY SRL 

Adress:  

Corso Sempione 172/5   

 

 

 

 

21052 Busto Arsizio VA Italy

 

Product’s name: 

START-S4XL   

   

Single phase for 230 Vac 

   2 

motors

EB TEChNOLOGY  S.r.l. 

Corso Sempione 172/5, 

 

21052 Busto Arsizio VA Italia 

tel. +39 0331.683310

fax.+39 0331.684423 

 

[email protected]   

www.ebtechnology.it

NOLOGO S.r.l. 

via Cesare Cantù 26, 

 

20020 Villa Cortese MI Italia 

tel. +39 0331.430457 

fax.+39 0331.432496 

 

[email protected]   

www.nologo.info

Содержание START-S4XL

Страница 1: ...230 Vac Lamp Motor 1 COMMON Motor 1 OPEN Motor 1 CLOSE Motor 2 COMMON Motor 2 OPEN Motor 2 CLOSE Open Limit Switch Mot 2 Clos Limit Switch Mot 1 Closing photocell Start Button 24Vac 24 Vac 12Vac elec...

Страница 2: ...ical limit switches should fail or during manual operations 2 Installation 1 Introduction START S4XL is the ongoing evolution of the START S4 electronic control unit completely compatible and equipped...

Страница 3: ...75 mm2 Use shielded cables if the length exceeds 30m and connecting the ground braid only from the side of the control unit Do not connect the cables in underground cases even if they are water tight...

Страница 4: ...OPEN M2 M 2 Closing 11 Output to connect motor no 2 pole CLOSE FCC M2 12 Input Closing limit switches motor no 2 FCA M2 13 Input Opening Limit Switches 2 FCC M1 14 Input for Closing limit switches of...

Страница 5: ...and if adjusted at the maximum power the door opens when the second door has finished the working time In next opening will the new value valid 0 Max SPEED SLOW DOWN Setting up of the speed of the sl...

Страница 6: ...8 9 10 1 2 7 3 ON REVERSING STROKE This function starts a closing thrust at the beginning or at the end of the manoueuvre to make easy the work of the electrical lock 4 ON Courtesy light In the output...

Страница 7: ...pening displacement will be at 2 seconds The closing displacement can be chosen with the trimmer displacement 7 X Leave in the OFF 8 OFF Time learning planned from the user Leave in OFF when used the...

Страница 8: ...put photocell always activated 8 ON Radio DECODE It activate the radio receiver 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 8 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7...

Страница 9: ...ry all codes is possible only when the gate is closed 1 Make sure that the gate is in closed position 2 Push the codes button until the L E D CODICE flashes AND release it Wait until the reset of the...

Страница 10: ...nt time the first motor closes 5 Press the TIMES button or START if the limit switches are not available The second motor stops wait until the first motor stops END OF LEARNING TIME if the limit switc...

Страница 11: ...switch of motor no 2 is not available The second motor stops the first motor CLOSES 9 a if the limit switch is available wait until motor no 2 stops The motor no 2 stops motor no 1 closes 10 Push the...

Страница 12: ...ls for the TEST function Now the control unit check the TEST function of all devices and the the gate opens with a little bit delayed 8 6 9 10 7 8 Make all connections to the TEST as shown in the manu...

Страница 13: ...989 harmonizing the legislation of the member countries regarding electromagnetic compatibility Reference to harmonized standards EN 61000 6 2 EN 61000 6 3 THE PRODUCT COMPLIES with the essential requ...

Страница 14: ...sous la seule responsabili du constructeur et si applica ble de son repr sentant autoris Busto Arsizio Va Italia 14 06 2007 ERNESTINO BANDERA Administrateur KONFORMIT TSZERTIFIKAT Der Unterzeichner be...

Отзывы: