NSB–6
System Module
PAMS Technical Documentation
Page 17
Issue 1 06/2000
E
Nokia Mobile Phones Ltd.
0.55
0.05 Vcc
0.85
0.05 Vcc
Vcc
GND
S
IG
O
UT
SIMC
ARD
D
ET
X
Battery Temperature
The battery temperature is measured with a NTC inside the battery pack.
The BTEMP line inside transceiver has a 100k pullup to VREF. The MCU
can calculate the battery temperature by reading the BTEMP line DC–
voltage level with a CCONT (N100) A/D–converter.
Pin
Name
Min
Typ
Max
Unit
Notes
3
BTEMP
0
1.4
V
Battery temperature indication
100k pullup resistor to VREF in phone
Battery package has NTC pull down resis-
tor:
47k +/–5%@+25C , B=4050+/–3%
2.1
5
10
3
20
V
ms
Phone power up by battery (input)
Power up pulse width
47
kohm
Service battery value
–5
5
%
100k pullup resistor tolerance
100k
VREF
TRANSCEIVER
R
T
BATTERY
BTEMP
BGND
BSI
VBATT
NTC
BTEMP
CCONT
10k