27

Display 83 - Control of task information displays 

 
        ************** 
        *            * 
        * SHOW TASK  * 
        * XXXXXXXXX  *   XXXXXXXXX is "STACKS", "MSG BUFS" or "FAST BUFS" 
        *            * 
        ************** 
 
Shows what information about tasks is currently shown in displays 84 - 87. 
 
To select the type of information select this display via menu. 
Type is changed in order STACKS -> MSG BUFS  -> FAST BUFS -> STACKS. 
So, if STACKS is currently displayed and you want to see FAST BUFS, you have to select this 
display twice via menu.  
 

"STACKS" 

shows free stack space in worst case. 

"MSG BUFS" 

shows the peak number of pending messages. 

"FAST BUFS" 

shows the peak number of pending fast messages. 

 

 

Display 84, 85 & 86 - Information about tasks 

 
        ++++++++++++++ 
        + aaaa bbbb  + 
        + cccc dddd  + 
        + eeee ffff  + 
        + gggg hhhh  + 
        ++++++++++++++ 
 

aaaa 

task 0,  8, 16 

bbbb 

task 1,  9, 17 

cccc 

task 2, 10, 18 

dddd 

task 3, 11, 19 

eeee 

task 4, 12, 20 

ffff 

task 5, 13, 21 

gggg 

task 6, 14 

hhhh 

task 7, 15 

 

Numbers tell how many stack memory locations have been empty in the worst case. So, if 
number is zero, stack has been full. 
 
Values are not stored to EEPROM. 
 
The task names are listed on help display. 
 

Display 87 - Information about OS_SYSTEM_STACK 

 
        ++++++++++++++        ############## 
        + aaaa  bbbb +        #  FIQ  IRQ  # 
        +            +        #            # 
        +            +        #            # 
        +            +        #            # 
        ++++++++++++++        ############## 
 

aaaa 

OS_SYSTEM_STACK 

 
   
Values are not stored to EEPROM. 
 

 

Содержание NetMonitor

Страница 1: ...1 Nokia NetMonitor Manual Version 0 5 Base document Flipo flipo gyral com PDF Enhancements to base document nobbi nobbi nobbi com Graphics nobbi ...

Страница 2: ...p Mode Mode Mode The execute mode is entered from the menu by scrolling and selecting or shortcut If the test index entered pertains to a test that resets a timer test 80 for example then the timer is reset as soon as the Ok button has been pressed in the menu and the data display mode takes over In other words the execute mode is of the one shot type To run another test in the execute mode the Fi...

Страница 3: ...of the path loss criterium C1 Range is 99 999 oooo type of current channel THR0 TCH HR subchannel 0 THR1 TCH HR subchannel 1 TFR TCH FR TEFR TCH EFR F144 TCH FR data channel speed 14 4 kbps F96 TCH FR data channel speed 9 6 kbps F72 TCH FR data channel speed 7 2 kbps F48 TCH FR data channel speed 4 8 kbps F24 TCH FR data channel speed 2 4 kbps H480 TCH HR data channel speed 4 8 kbps subch 0 H481 T...

Страница 4: ...20 s 0 31 20 s xxx in dedicated mode j Hopping channel 0 Single RF channel 1 RF hopping channel mm mobile allocation index offset MAIO Range 00 to 63 xx when H 0 nn hopping sequence number HSN Range 00 to 63 xx when H 0 Display 3 Serving cell 1st and 2nd neighbour aaabbbcccddd SCH C1 rx C2 aaabbbcccddd 1CH C1 rx C2 aaabbbcccddd 2CH C1 rx C2 ef gh 1N 2N 1 row serving cell information 2 row 1 neighb...

Страница 5: ... B cell is barred N cell is normal priority L cell is low priority Display 6 Network selection display aaabb aaabb LReg 1_For aaabb aaabb 1_Pre 2_For aaabb aaabb 2_Pre 3_For aaabb aaabb 3_Pre 4_For This display shows the last registered networks country code MCC and network code MNC as well as the codes for four forbidden networks and the first 3 preferred networks If a three digit MNC is used GSM...

Страница 6: ...rting of the six strongest cells with known and allowed NCC part of BSIC irrespective of the band used 01 The MS shall report the strongest cell with known and allowed NCC part of BSIC in each of the frequency bands in the BA l ist excluding the frequency band of the serving cell The remaining positions in the measurement report shall be used for reporting of cells in the band of the serving cell ...

Страница 7: ...ltiframe ee Downlink signalling failure value If value is negative 0 is shown Maximum value is 45 When mobile is on TCH then xx is shown ff Gain value on TCH SDCCH range is 0 93 ggggg VCTCXO AFC DAC control range is 1024 1023 hhh Serving cell channel number Display 11 Network parameters CC aaa NCbbb MCC MNC LAC ccccc LocAreaCode CH dddd ServChannel CID eeeee CellId aaa MCC value in decimal MCC Mob...

Страница 8: ...f switched mode DTX ON MS uses DTX DTX OFF MS does not use DTX DTX DEF MS use default state of DTX NOTALLOWED BS does not allow MS to decide if it uses DTX or not bbb default state of DTX in MS The value is either ON or OFF ccc is DTX value from BS MAY BS allows MS to decide if it uses uplink DTX or not USE BS controls MS to use DTX on uplink NOT BS controls MS not to use DTX on uplink Display 14 ...

Страница 9: ...TS_TEST can be off If there is no legal carrier number in SIM phonebook location 33 GSM900 1 124 GSM1800 512 885 the display shows that BTS_TEST is off Also if the mobile was already registered to some carrier before switching BTS_TEST status the display can show a different value from the one in EEPROM Display 18 Lights status control Forces keyboard and display lights on off while displaying any...

Страница 10: ...charging LiFul PWM has been below the battey full limit for a certai n time that is specified for full battery LiHot Li ion hot charging LithC Charging of Lithium ion battery LiTxO TX on and Li charging going LNFTx TX on Li charging going and battery is not full anymore M_Che Maintenace charging checks MaBFD Maintenace BFD charging Maint Maintenance charging TmpFa Charging off because of battery N...

Страница 11: ...olt Letters E C D R I A T and V are displayed if values are shorter than 4 digits Eaaa DerivCount membership function set range 0 00 1 00 decimal point is not shown e g 0 23 is shown as 023 Cbbb ChargeAmount membership function set range 0 00 1 00 decimal point is not shown e g 0 23 is shown as 023 Dccc VolDiffToMax membership function set range 0 00 1 00 decimal point is not shown e g 0 23 is sho...

Страница 12: ...f battery s percentage level 0 100 gggg current consumption indicated by PSM deci mA hhh battery s temperature C Only for Li battery iiii charged capacity mAh into battery jjjj tells what is the next capacity target to reach next battery bar level mAh Display 24 BSI values aaaa bbbb V_inst V_avg cccc BSI value dddd Elapsed time eeee ffff RST_m RST_h aaaa bbbb cccc BSI value dddd minutes elapsed si...

Страница 13: ...X Sequence number k Phone mode S slave H host Display 35 Reasons for SW resets aaaaa Reset reason bbbbbbbb Task name aaaaa last reset reason NORM Probably normal power up UNKNO Default value reset reason is unknown HW WD ASIC watchdog timeout SWDSP DSP recovery reset SWSIM SIM contact failure reset SWIDL Idle task not running reset STACK Task stack overflow bbbbbbbb Name of running task before res...

Страница 14: ...5 Incoming calls barred within the CUG 57 bearer capability not authorized 65 bearer service not implemented 68 ACM equal to or greater than ACMmax 69 requested facility not implemented 88 incompatible destination MM 0 no error 2 IMSI unknown in HLR 3 illegal MS 4 IMSI unknown in VLR 5 IMEI not accepted 6 illegal ME 11 PLMN not allowed 12 location area not allowed 13 roaming not allowed in this lo...

Страница 15: ...a counter of successful handovers max 9999 from GSM900 to GSM900 bbbb counter of successful handovers max 9999 from GSM1800 to GSM1800 cccc counter of successful handovers max 9999 from GSM 900 to GSM1800 dddd counter of successful handovers max 9999 from GSM1800 to GSM900 eee counter for failed handovers max 999 from GSM900 to GSM900 fff counter for failed handovers max 999 from GSM1800 to GSM180...

Страница 16: ...o GSM1800 lll counter of successful back to previous normal INTRA CELL channel attempts max 999 from GSM1800 to GSM900 Counters will stop when they reach their maximum To initialize the counters to zero select display 40 Also display 60 initializes these counters Display 43 L2 display T200MS aaaa T200 MS GSM T200BS bbbb T200 BS GSM T200MS cccc T200 MS DCS T200BS dddd T200 BS DCS aaaa GSM900 counts...

Страница 17: ...on updating can be checked from the display 10 chapter 3 1 10 by taking the difference of current T3212 counter value and T3212 timeout value Display 51 SIM information aaa bbb ccc VSel Bau SAl dddddddd SCond CStop f g hh ii PIN12 PUK12 j kkkk ATR FE PE aaa SIM voltage selection type 5 3 or 3 5 bbb SIM baudrate 372 64 32 or 0 ccc Clock stop allowed Yes or No dddd Clock stop condition Up Down xxxxx...

Страница 18: ... failed deallocations is not zero Display 57 Memory status before reset aaaaaaaaaaaa Status of aaaaa stacks bbbbbbbb Block sets aaaaaa Status of each stack before reset First position contains the status of stack 0 second position the status of stack 1 and so on The last position contains the status of System stack Number of stacks depends on the current configuration of SW Possible values for eac...

Страница 19: ...splay aaaaa bbbbb NOPswGSM DCS ccccc ddddd Sync GSM DCS eeeee fffff reselG G D D ggggg hhhhh reselG D D G aaaaa GSM900 counter for MDI_NO_PSW_FOUND message received from DSP in decimal form max 99999 bbbbb GSM1800 counter for MDI_NO_PSW_FOUND message received from DSP in decimal form max 99999 ccccc GSM900 counter for synchronization measurement attempts in decimal form If counter value is over 99...

Страница 20: ...obile originated MT Mobile terminated IN Internal ME CS sw ccc count of all MO call attempts made ddd count of succeeded MO calls eee count of all call setups received fff count of succeeded MT calls On poweroff the values of the counter displays are stored onto the EEPROM where they will be read during power on To initialize the counters to zero select display 60 Counters are automatically reset ...

Страница 21: ...ters are automatically reset to zero when they exceed their maximum value Display 66 SMS timeout counters 51xx 61xx aaa bbb cc TR1 TR2 TRA ddd eee ff TC1 TC2 SCH SMS timeout counters 7110 aaa bbb TR1 TR2 ccc fff TRA SCH ddd eee TC1 TC2 aaa Counter for TR1M timeouts SMR Layer incoming RP ACK timed out bbb Counter for TR2M timeouts SMR Layer outgoing RP ACK timed out cc Counter for TRAM timeouts RET...

Страница 22: ...ancements in decimal format The control word is sent to the DSP in mdi audio configure message Prior using this display the control word must be written to location 31 32 of SIM card in decimal format When the display 71 72 is choosen from the menu EXECUTE MODE the control word is sent to the DSP in mdi audio configure message immediately Mdi audio configure message is also sent every time when th...

Страница 23: ...he EEPROM Display 75 Audio path status Mod aaaaaaaa ExtAudStatus AudReq bbbb AudioRequest AccMod cccc AccessoryMod H2Path dd HFU2Path aaaaa external audio status values are HP HF HEADSET EXT and HP_OFFHO bbbb audio_request bitmap in hex contents masks are specified in AUD_DATA H cccc Accessory audio mode dd HFU 2 path Display 76 Ear downlink audio display Example Vaa Pbbb V0A P125 EVol PeakVal Ccc...

Страница 24: ...RVAD TVAD aaa Electro acoustic attenuation of echo from DSP point of view in dB Decimal point and sign is not shown E g 10 5dB would be displayed as 105 0 5 dB would be displayed as 5 20 log10 Q15 bbb Adaptive attenuation of echo Decimal point is not shown 20 log10 Q15 ccc Total echo return loss Decimal point is not shown 20 log10 Q15 ddd RX attenuator gain in dB Decimal point and sign is not show...

Страница 25: ...ormat ee e Level of the microphone signal level detector in dB format Requires log10 function in MCU 16 bit signed value in DSP 0 dB 32768 ff f Level of the signal after earpiece equalizer in dB format Requires log10 function in MCU 16 bit signed value in DSP 0 dB 32768 The display is reset and restarted when a call is placed When the call is terminated the display is frozen to show the last value...

Страница 26: ...enabling is stored onto the EEPROM Display 82 Test timer display aaaaa bbbbb PwrOn InServ ccccc ddddd NSPS TxON TIMERS eee Timers Status aaaaa timer for how long the phone has been powered on bbbbb timer for how long the phone has been in service ccccc timer for no service power save state ddddd timer for how long the transmitter has been on eee state of timers ON OFF All the values are shown in o...

Страница 27: ... in worst case MSG BUFS shows the peak number of pending messages FAST BUFS shows the peak number of pending fast messages Display 84 85 86 Information about tasks aaaa bbbb cccc dddd eeee ffff gggg hhhh aaaa task 0 8 16 bbbb task 1 9 17 cccc task 2 10 18 dddd task 3 11 19 eeee task 4 12 20 ffff task 5 13 21 gggg task 6 14 hhhh task 7 15 Numbers tell how many stack memory locations have been empty...

Страница 28: ...splay 89 Information of the current Hw and TXT versions HW aaaa HW Version TXT bbbbbbb Text Version aaaaa Hardware version e g 2350 bbbbbb Text version e g U190199 Display 99 7110 only FBUS mode and Accessory mode Ead aaaa EAD value Mod bb acc status MODE cccc FBUS moden aaaa bb type of connected audio accessory as in display 75 cccc currently selected data transfer mode FBUS MBUS IRDA AT Display ...

Страница 29: ... will deactivate the netmonitor menu so display 491 and display 753 will do the same There is no such feature like sending SMS for nothing or to do free calls for 90 seconds To reactivate the netmonitor menu you have to follow procedures like use Logomanager http www logomanager co uk use NetMonitor from A Schmidt http www aschmidt de use Monitor from Nobbi http www nobbi com monitor use PCLocals ...

Отзывы: