Display 74 - DSP audio enhancements 1 (DRC)
++++++++++++++ Example: ++++++++++++++ ##############
+ aaa bbb + + 101 408 + #DSigL USigL #
+ ccc + + 480 + # NseLvl#
+ dd ee + + 01 03 + # DTbl UTbl #
+ + + + # #
++++++++++++++ ++++++++++++++ ##############
aaa
Downlink signal level in dB, calculated using DRC level measuring block.
Decimal point and sign is not shown, ie. -10.5 is show 105.
bbb
Uplink signal level in dB, calculated using DRC level measuring block. Decimal
point and sign is not shown, ie. -10.5 is show 105.
ccc
Background noise signal level in dB, calculated using DRC level measuring
block, decimal point and sign is not shown, ie. -10.5 is show 105.
dd
Downlink DRC table value, shown in decimal integer, two digits.
ee
Uplink DRC table value, decimal integer, two digits.
The display is reset and restarted when call is taken (if FT display counters are enabled).
When call is terminated the display is frozen to show last values. Display values will not
be saved to the EEPROM.
Display 75 - Audio path status
++++++++++++++ ##############
+Mod:a #ExtAudStatus#
+AudReq: bbbb+ #AudioRequest#
+AccMod: cccc+ #AccessoryMod#
+H2Path: dd + #HFU2Path #
++++++++++++++ ##############
aaaaa
external audio status, values are: HP, HF, HEADSET, EXT and HP_OFFHO
bbbb
audio_request bitmap in hex, contents (masks) are specified in AUD_DATA.H
cccc
Accessory audio mode
dd
HFU-2 path
Display 76 - Ear (= downlink) audio display
++++++++++++++ Example: ++++++++++++++ ##############
+ Vaa Pbbb + + V0A P125 + #EVol PeakVal#
+ Cccc CAddd + + C000 CA001 + #CutOff COAve#
+PAeee + +PA353 + #PkAver #
+ + + + # #
++++++++++++++ ++++++++++++++ ##############
aa
Volume level.
bbb
Peak value of downlink audio signal during last frame in dB, decimal point and
sign is not shown, ie. -10.5 is show 105.
ccc
Cut off counter value of last frame. This counter counts how many samples are
saturated during last frame.
ddd
Moving average of cut off counter, decimal point and sign is not shown, ie. -
10.5 is show 105.
eee
Moving average of peak levels.
The display is reset and restarted when call is taken (if FT display counters are enabled).