IP100 Series Installation Guide
23
Using an External Modem
Table 2-1 shows the meanings of some of these commands.
B.
Set the DIP switches as shown in Table 2-2.
Table 2-1. US Robotics AT Commands
Command
Meaning
Y0
Load profile 0 from VRAM
&B
Set serial port data rate to modem to modem
connection rate
&H1, &IO, &R2
Set appropriate flow control
&N6, &U6
Set connection to 9600 bps
S0=1
Answer after one ring
&W0
Write settings for profile 0 to NVRAM
Table 2-2. US Robotics DIP Switches
DIP Switch
Position
Meaning
1
Down
Override DTR
5
Up
Answer incoming calls
7
Up
Load configuration from NVRAM
instead of using defaults
8
Down
Dumb mode