background image

6

www.noirot.com.au

No. of the
period

The Day will now be flashing.

Set the current day (i.e. 1 for Monday, 2 for Tuesday, etc.), then press

to confirm.

The time and day are now set.

To display the current time during normal operation, briefly press the

button.

The time will be displayed for 3 seconds.

PROGRAMMING THE TIMER

It is possible to set up to 3 On/Standby periods per day using the timer mode. Each day can be
programmed individually or all days can be programmed at once.

Press the

button for 2 seconds to enter the programming mode

The Day will now be blinking

Use the

and

buttons scroll to the required day. Note that after Day 7, ‘ALL’ will be

displayed. Use this setting to program every day.

Press the

button to confirm

Period 1 settings are now displayed

Use the

and

buttons to select the time that you

want the heater is to turn

ON

.

When a time is displayed a red triangle appears on the
display below

FROM

Press the

button to confirm

Use the

button to select the time that you want the

heater is to return to

STANDBY

The red triangle in now displayed below

TO

, indicating the

time the heater is set to revert to

STANDBY

mode.

Press the

button to confirm

Period 2 settings are now displayed. Repeat the above steps for Period 1 to set the times that
the heater is to turn

ON

and return to

STANDBY.

If no more On/Standby periods are required for the day, continue to

press until the Day is

again displayed.

Repeat the above steps for each day heating periods are required.

To exit to programming mode press

until the

DAY

is displayed. Press the

button

until

EXIT

is display on the display.

Press the

button to confirm to exit programming

Briefly pressing the

button when the heater is in AUTO Mode will display the time left in a

heating period or the lapsed time until the next heating period starts.

No Pr

is displayed if no

more heating periods are programmed for that day.

Note:

The temperature can be adjusted at any time during a heating period. Simply press the
or

buttons to adjust the room temperature.

Содержание 7358-3T

Страница 1: ...Plus Digital Timer Electric Convection Panel Heater In Order To Qualify For Your Lifetime Warranty Please Visit our Website and complete the Online Registration www noirot com au Operating Installation Instructions ...

Страница 2: ...erred a screwdriver No 1 Fig 1 Fit the wall bracket to the wall with suitable fixing method according to the surface you mount the heater on not included Place the heater on to the bracket and clip into position Note To centre your appliance laterally on the wall use the hole marked 2 Model Height A B C 7358 3T 440 420 208 106 7358 5T 440 580 178 201 7358 7T 440 745 320 210 7358 8T 440 900 405 248...

Страница 3: ...Over Temperature Safety Thermal Cut Out Switch is activated the heater will automatically switch off to limit the temperature to a safe value To reset the thermal cut out simply switch the heater off unplug it from the power point and remove the obstruction s Plug the heater back in and switch it on The thermal cut out switch will reset after a few minutes and the heater will function normally PAN...

Страница 4: ...fore plugging it in IMPORTANT DO NOT plug heater into a Power Board Double Adaptor or Extension Lead USING YOUR HEATER FOR THE FIRST TIME Remove the heater from its packaging please dispose of packaging responsibly Contents should be as follows 1 Heater 2 Wall bracket pre attached to the back of the heater 3 Instructions for installation and use 8 page booklet Ensure the heater is correctly mounte...

Страница 5: ...e is set to COMFORT Use the and buttons to set the required room temperature The temperature is increased or decreased in 0 5 C increments and ranges from 11 C to a maximum of 27 C The symbol on the display indicates that the element is energised Once the room temperature has stabilised the heating element will cycle on and off to maintain the room temperature Press to return the heater to STANDBY...

Страница 6: ...ow FROM Press the button to confirm Use the button to select the time that you want the heater is to return to STANDBY The red triangle in now displayed below TO indicating the time the heater is set to revert to STANDBY mode Press the button to confirm Period 2 settings are now displayed Repeat the above steps for Period 1 to set the times that the heater is to turn ON and return to STANDBY If no...

Страница 7: ...o periodically clean the air vents using the soft brush on your vacuum cleaner as dense accumulation of dust will cause the heater to over heat and trigger the safety thermal cut out switch SPECIFICATIONS Model Power W Current A Height A B C 7358 3T 1000 4 2 440 420 208 106 7358 5T 1500 6 3 440 580 178 201 7358 7T 2000 8 3 440 745 320 210 7358 8T 2400 10 0 440 900 405 248 Please note Heater temper...

Страница 8: ...ct at the place of purchase 3 If the product is deemed faulty and under warranty the place of purchase of the product will order a replacement heater to which Noirot Australia at our cost will deliver the heater to the place of purchase 4 The consumer will then be required at their cost to pick up the replacement heater from the place of purchase 5 If the heater is faulty but not deemed to be unde...

Отзывы: