30
Connections (B+, B-) have one terminal each.
STANDARD_PARAMETER
Parameter
Software
standard
parameter
RANGE
Unit
DESCRIPTION
Drive menu
Accel Max Speed
1.8
0.2 to5.0
seconds
Sets the rate (in seconds) at which the speed command
increases when throttle is applied with the speed limit
pot is in its maximum speed position, and the vehicle is
traveling forward. Larger values represent slower
response.
Accel Min Speed
5.0
1.8 to 8.0
seconds
Sets the rate (in seconds) at which the speed command
increases when throttle is applied while the speed limit
pot is in its minimum speed position, and the vehicle is
traveling forward. Larger values represent slower
response
Decel High Speed
0.6
0.2 to 1.5
seconds
Sets the rate (in seconds) that is used to slow down
the vehicle when it is traveling forward at high speed
and throttle is reduced. Larger values represent
slower response.
Decel Low Speed
1.5
0.6 to 8.0
seconds
Sets the rate (in seconds) that is used to slow down the
vehicle when it is traveling forward at low speed and
throttle is reduced. Larger values represent slower
response.
Rev Accel Max Speed
1.8
0.2 to 5.0
seconds
Sets the rate (in seconds) at which the speed command
increases when throttle is applied while the speed limit
pot is in its maximum speed position, and the vehicle is
traveling in reverse. Larger values represent slower
response.
Rev Accel Min Speed
5.0
1.8 to 8.0
seconds
Sets the rate (in seconds) at which the speed command
increases when throttle is applied while the speed limit
pot is in its minimum speed position, and the vehicle is
traveling in reverse. Larger values represent slower
response.
Rev Decel High Speed
0.6
0.2 to 1.0
seconds
Sets the rate (in seconds) that is used to slow down the
vehicle when it is traveling in reverse at high speed and
throttle is reduced. Larger values represent slower
response.
Rev Decel Low Speed
1.0
0.6 to 8.0
seconds
Sets the rate (in seconds) that is used to slow down the
vehicle when it is traveling in reverse at low speed and
throttle is reduced. Larger values represent slower
response.
Keyoff Decel
0.7
0.2 to 4.0
seconds
Sets the rate (in seconds) that is used to slow down
the vehicle when it is traveling in reverse at low speed
and throttle is reduced. Larger values represent
slower response.
https://forklift-manuals.jimdofree.com