53
The
Plug Screw of port for adding oil is ventilating. When lower, the air will come out
from the tank, it might take out little oil vapor. So, it might appear little oil stains on the plug. Wait a little
and ensure, that there is no oil leakage.
For the electric current of the Relay for the lifting motor is very big, and work
continually hourly, the contact terminal of the relay is easy damaged. Please check it continually.
The Magnet valve is a wearing part. If the forks automatically lower after lifting, the
magnet valve may be blocked or damaged, remove it to clear or replace.
HYDRAULIC PIPE
For shocking, the joint of the hydraulic pipe and hydraulic pipe might be loosed and
leak oil, so usually check and tighten it.
https://forklift-manuals.jimdofree.com