Use and Maintenance Manual model “H14 V SHAPE”

    

36 

ENGLISH

ALARM CODE

REASON

04

SMOKE TEMPERA-

TURE

Combustion in the brazier is not optimal as it 

is clogged or the inner passages of the ap-

pliance are clogged.
The tangential fan (if present) is 

not working properly or is damaged.

SOLUTION

Switch the product off and back on again, 

activating the cleaner; adjust the 

combustion with the “P/E mix”.
If the problem persists, contact the Support 

Service

ALARM CODE

REASON

05

EXTRACTOR 

ROTATIONS NOT 

RESPECTED

The rotations of the smoke extractor show a 

loss of efficiency due to obstruction of 

the fan or a drop in voltage.

SOLUTION

If the problem persists, contact the Support 

Service

ALARM CODE

REASON

06

FAULTY SMOKE 

EXTRACTOR

Smoke extractor encoder not working or 

not connected correctly

No power supply to the smoke extractor

The smoke extractor is blocked

SOLUTION

If the problem persists, contact the Support 

Service

ALARM CODE

REASON

07

GEARMOTOR  

ROTATIONS NOT 

RESPECTED

PELLET LOADING

The rotations of the gearmotor present a 

loss of efficiency due to a drop in voltage.

SOLUTION

If the problem persists, contact the Support 

Service

ALARM CODE

REASON

08

PELLET LOADING 

GEARMOTOR 

FAULT 

Gearmotor encoder not working or not 

connected correctly

No power to gearmotor

SOLUTION

If the problem persists, contact the Support 

Service

ALARM CODE

REASON

09

PELLET LOADING 

AUGER 

BLOCKED

Possible foreign body or sawdust preventing 

correct movement.

SOLUTION

Empty the tank and check for foreign bodies.

If the problem persists, contact the Support 

Service

ALARM CODE

REASON

10

PELLET 

LOADING AUGER 

POWER SUPPLY 

DEFECT

No power supply or power supplied by elec-

tronic control unit not 

correct

SOLUTION

If the problem persists, contact the Support 

Service

ALARM CODE

REASON

11

MINIMUM 

PRESSURE PASCAL

The sensor does not detect negative air 

pressure inbound of the appliance.

SOLUTION

Check the door and ash pan are   

closed correctly, check if the air intake 

tube is obstructed. 

If the problem persists, ccontact the Support 

Service.

ALARM CODE

REASON

12

BRAZIER CLEANER 

FAULT

The cleaner has not completed 

movement and is not found in the 

correct position or the fire door is not closed 

correctly.

SOLUTION

Check if the door is closed correctly, reset 

the alarm and wait for the product to go to 

OFF status. Disconnect and reconnected 

current, the system re-activates the clean-

er, checking the correct position again.

If the problem persists, contact the Support 

Service

ALARM CODE

REASON

13

NEGATIVE PRES-

SURE IN CHIMNEY 

FLUE

The chimney flue is blocked.

The sensor reading the negative pressure is 

not working properly.

SOLUTION

Check the chimney flue is not blocked, con

-

tact a chimney sweep to clean it.

If the problem persists, contact the Support 

Service

ALARM CODE

REASON

14

THERMOSTAT MAN-

UAL RESET

You have to manually reset 

the thermostat connected to the hopper

.

Combustion in the brazier is not optimal as 

the brazier is clogged or the inner passages 

of the appliance are clogged.
Ventilation, where present and active, 

may not be working properly.

SOLUTION

Reset the thermostat by pressing the button 

on the back of the appliance.
Switch off the product, switch on the system 

again to activate the cleaner and adjust 

combustion with the P/E mix.
If the problem persists, contact the Support 

Service.

Содержание H14 V SHAPE

Страница 1: ...EN Installation use and maintenance manual H14 V SHAPE...

Страница 2: ...appropriate place having carefully consulted it Improper installation maintenance not carried out correctly and improper use of the product relieve the manufacturer of any liability towards people or...

Страница 3: ...8 Description of remote controls 21 8 1 Description of receiver 21 8 2 Description of handheld device keys 21 8 3 Description of handheld device display 22 8 4 Flat battery signalling 22 8 5 Concise i...

Страница 4: ...ty and maintenance of safety devices do not remove or bypass this devices 1 3 IMPROPER USE The product must be intended for the use for which it was expressly designed for any other use the manu factu...

Страница 5: ...on conforming installation with that specified by the manufacturer refer to the installation and use manual supplied with the appliance further damage caused by wrong intervention by the user in an at...

Страница 6: ...ng it less comfortable and reducing the overall efficiency of the system Hermetic prod ucts can also be installed in the presence of forced ventilation or in premises which can go into negative pressu...

Страница 7: ...ms garage etc and must have a net useful section equal or higher than 80 cm2 pellet burning stoves and thermostoves EN 14785 and 100 cm2 for boilers EN 303 5 The air intake is not necessary for instal...

Страница 8: ...rm of dis charge not planned by legislation in force in the country of installation In Italy only roof discharge is permitted 3 4 CHIMNEY POT The standard UNI 10683 states the stack must meet the foll...

Страница 9: ...parts such as wood etc In both cases insert adequate insulation 5 be tween the chimney flue and the attic You are advised to check and comply with the plate data of the chimney flue in particular the...

Страница 10: ...ician NOBIS SRL cannot be held in any way liable in the event of non compliance with the installation and start up standards of its products 3 8 PRODUCT UNPACKING Packaging is composed of boxes in rec...

Страница 11: ...ide panel from the packaging and insert the hooks placed in the lower part of the same in the slits placed on the base of the product Bring the panel to the vertical position and fasten the upper part...

Страница 12: ...ll the steps to perform the hydraulic connection of the appliance to the dwelling system are illustrated The connection of the product to the hydraulic system must be carried out exclusively by specia...

Страница 13: ...r civil use before installing the appliance is paramount EXPANSION VESSEL The product is equipped with an expansion vessel to compensate for the increase in water pressure inside the boiler in case of...

Страница 14: ...a pavimento Riscaldamento a termosifoni Valvola a tre vie Risc Sani Accumulo ACS Bollitore Flussostato ACS Valvola miscelatrice Accumulo acqua tecnica Puffer 11 12 13 14 15 16 17 18 19 8 DIAGRAM 00 D...

Страница 15: ...re vie Risc Sani Accumulo ACS Bollitore Flussostato ACS Valvola miscelatrice Accumulo acqua tecnica Puffer 11 12 13 14 15 16 17 18 19 1 2 3 4 5 6 7 2 9 11 12 12 13 14 10 8 15 16 17 18 DIAGRAM 01 DIREC...

Страница 16: ...a tre vie Risc Sani Accumulo ACS Bollitore Flussostato ACS Valvola miscelatrice Accumulo acqua tecnica Puffer 11 12 13 14 15 16 17 18 19 1 2 3 4 6 7 2 9 11 12 12 13 14 10 8 18 10 19 DIAGRAM 02 TECHNIC...

Страница 17: ...parete Riscaldamento a pavimento Riscaldamento a termosifoni Valvola a tre vie Risc Sani Accumulo ACS Bollitore Flussostato ACS Valvola miscelatrice Accumulo acqua tecnica Puffer 6 7 8 15 16 17 DIAGR...

Страница 18: ...ANCE The maintenance operations excluding routine cleaning explained in the relevant paragraph must be carried out by authorised technical staff Remember before carrying out any maintenance operation...

Страница 19: ...E TREATMENT DISEGNATORE SCALA SCALE FORMATO FORMAT STATO STATUS REVISIONE REVISION TOLLERANZE GENERALI SECONDO LA CLASSE UNI EN 22768 mK GENERAL TOLERANCES AS PER UNI EN 22768 mK NOBIS S r l N DISEGNO...

Страница 20: ...ded by inserting pellets from the upper part of the product opening the door Ensure the content of the bag of pellets does not fall around the edges of the tank paying particular attention to centring...

Страница 21: ...y re mote board placed at the back of it which allows basic management of the functions in the event the handheld device is faulty or not working properly 1 Serial connection use by authorised staff O...

Страница 22: ...nal will confirm the change OK From STAND BY mode pressing allows to obtain an overview of the actual and active device status as shown in the following figure 8 4 FLAT BATTERIES SIGNAL If batteries a...

Страница 23: ...tying ACTIVE COMFORT CLIMA RESTART FROM COMFORT CLIMA FINAL CLEANING OFF ALERT see specific paragraph FLAME OVERHEATING PELLET OVERLOAD 8 5 CONCISE ICONS DIAGRAM 1 2 4 3 MEANING H2 O STANDBY FAULT PRE...

Страница 24: ...eference standard thermostat OPERATING PROCEDURE MENU USER SETTINGS SETTINGS PROBE CALIBRATION Access menu by pressing Scroll down entries to select USER SETTINGS using Access menu by pressing OK OK B...

Страница 25: ...signalling causes switching off of the prod uct as well as resetting of any alarms For models with an automatic cleaner during the switch on phase the product activates a brazier cleaning phase befor...

Страница 26: ...ermines the temperature gradient according to which the appliance must restart STATUS SCREEN To see the shutting down of the appliance while in COMFORT CLIMA mode screen must be displayed To see that...

Страница 27: ...d so as to turn it off once the temperature in the room where the product is in stalled has been reached by means of the remote control and using only an external thermostat for the device environment...

Страница 28: ...LEAN ING status before starting the function The number expressed in seconds indicates the rota tion time of the auger during the loading phase After this time is up the auger stops automatically afte...

Страница 29: ...m by pressing the key and pass to edit extraction OK Edit the extraction setting keys The values vary from 5 reduction in extraction in to 5 increase in extraction in Confirm by pressing the key and e...

Страница 30: ...ing system in the presence of DHW storage tank with SUMMER settings OPERATING PROCEDURE MENU USER SETTINGS SETTINGS SEASON Access menu by pressing Scroll down entries to select USER SETTINGS using Acc...

Страница 31: ...ND BY screen use the key repeating the operation multiple times 12 10 ANTICONDENSATION exhaust fumes temperature This function ensures that the temperature of exhaust gases remains higher than condens...

Страница 32: ...ge or by pressing button An acoustic signal will confirm the change OK The operation is the same as the one described in the basic diagram with the only difference that here the product exchanges dire...

Страница 33: ...heating by means of a con tact or immersion probe not provided always to be connected on the back side of the product The new stand by screen is shown below STAND BY SCREEN 1 2 2 It shows the technica...

Страница 34: ...LEANING OFF WAITING FOR FLAME FLAME PHASE RESTART PHASE DESCRIPTION Room temperature set on MAN mode In this case the appliance will operate only when firebox power is set it NEVER switches to eco mod...

Страница 35: ...on tact an authorized technician to solve the problem Anomaly to the upstram probe mo nitoring the water temperature in the technical water storage tank hot water tank please contact an authorized tec...

Страница 36: ...ALARM CODE REASON 10 PELLET LOADING AUGER POWER SUPPLY DEFECT No power supply or power supplied by elec tronic control unit not correct SOLUTION If the problem persists contact the Support Service AL...

Страница 37: ...ION If the problem persists please contact the Assistance Service ALARM CODE SOLUTION 27 PUMP FAILURE The pump does not worlk properly or cannot start SOLUTION If the problem persists please contact t...

Страница 38: ...detergents or diluents causes damage to the surface of the product 19 1 CLEANING THE FIREPLACE Open the fire door using the specific tool and vacuum the slide bringing the ash to the brazier dismantle...

Страница 39: ...h an abrasive function avoiding use of products with additives that could over time wear the seals glass and paint Do not switch on the appliance if the glass is damaged Contact the support service to...

Страница 40: ...hich are indispensable for correct appliance operation PARTS FREQUENCY TIME Ash pan approx time 7 DD Glass 2 3 DD Extraction pipe 1 SE Door seal ash pan 1 SE Tube bundle scraper where present 7 DD Chi...

Страница 41: ...ON MANUAL RESET THERMAL SWITCH CONTACT DOOR ASH PAN 1 PELLET TANK 2 220V SOCKET WITH ON OFF SWITCH AND FUSE SAFETY VACUUM SWITCH VENTILATION FRONT PC CONNECTION technical support only USB CONNECTION t...

Страница 42: ...Use and Maintenance Manual model H14 V SHAPE 42 ENGLISH DATE NOTE...

Страница 43: ...Use and Maintenance Manual model H14 V SHAPE 43 ENGLISH DATE NOTE...

Страница 44: ...N 11 25037 Pontoglio BS www nobisfire it Cod 110 002 0014N_S1 Nobis Srl cannot be held in any way liable for any errors in this manual and considers itself free to change the features of its products...

Отзывы: