InSight Radar (IR2) (IR2-HD2 and Higher Models)
26
Hardware Installation
Installer’s Guide
Power Supply Requirements
Supply voltage used
Maximum current drain
Allowable voltage range
12 VDC
5A (IR2-HD2)
5A(IR2-4D)
6A(IR2-4x)
7A (IR2-6x)
8A(IR2-12x)
10.2 to 41.6V
24 VDC
(required for double speed
support in Nobeltec Admiral)
2.5A (IR2-HD2)
2.5A (IR2-4D)
3A(IR2-4x)
3.5A (IR2-6x)
4A(IR-12x)
5.4A (IR2-25x)
18.6 to 41.6V
Caution
: AC power supply cannot be used.
Plug the included power supply cable into the connector on the Control Box
labeled “Power”. Make sure to place the fuse and connector in a dry splash-free area.
When extending the cable, use a suitable cable as indicated below.
Supply voltage used
Cable Conductor
Cable Max Length
12 VDC
12 Gauge
25 Feet
10 Gauge
60 Feet
24 VDC
12 Gauge
70 Feet
10 Gauge
120 Feet
Figure 3.17—Cable #2: Power supply cable