NIVELCO Nivotrack MI-5 Series Скачать руководство пользователя страница 9

mia505en2102p 

 9 / 16

 

 

3.

 

TECHNICAL DATA 

 

TYPE 

STANDARD 

MI

 

MINI 

MY

 

PLASTIC COATED VERSION

 

MX

 

Measured process value 

Liquid level, distance 

Nominal length (L) 

0.3…3.5 m (1…11.5 ft) 

0.3…1.5 m (1…4.9 ft) 

0.3…3 m (1…10 ft) 

Material of the tube 

Stainless steel: DIN 1.4571 

PFA coated, Stainless steel: DIN 1.4571 

Max. medium pressure* 

25 bar (2.5 MPa, 360 psi) 

16 bar (1.6 MPa, 230 psi) 

3 bar (0.3 MPa, 43.5 psi) 

Medium temperature* 

40…+90 °C (

40…+194 °F) 

Standard float diameter / material 

(included)* 

54 x 60 mm (

2.1 x 2.36") cylindrical /  

1.4404 (316L) 

28 x 29 mm (

1.1 x 1.15") / 

1.4404 (316L) 

76 x 87 mm (

3 x 3.4") cylindrical  

/ PVDF 

Medium density 

54 mm (

2.1") float min. 0.8 g/cm³; 

54 mm (

2.1") Titanium float min. 0.55 g/cm³  

95 mm (

3.74") float min. 0.55 g/cm³; 

124 mm (

4.88") float min. 0.4 g/cm³ 

PVDF float min. 0.7 g/cm3 

Material of wetted parts 

Stainless steel: 1.4571 (316Ti), floats: see “Float Selection” 

PFA, PVDF, PP 

Ambient temperature 

40…+70 °C (

40…160 °F) 

Output 

Analogue 

4…20 mA (limit values: 3.9…20.5 mA)  

Digital communication 

HART

®

 (minimum loop resistance: 250 

Error indication 

Output signal = 22 mA or 3.8 mA 

Output load 

R

t

 = (U

t

12.5 V) / 0.02 A; U

t

 = power supply voltage 

Power supply 

12.5…36 V DC 

Electrical protection 

Class III 

Ingress protection 

IP65 

Process connection 

As per order code 

Electrical connection 

Hirschmann EN 175 301-803-A (DIN43650) 

Weight 

2.9 kg + measuring probe: 0.6 kg/m 

(6.4 lb + m. probe: 0.4 lb/ft) 

2.9 kg + measuring probe: 0.3 kg/m 

(6.4 lb + m. probe: 0.2 lb/ft) 

2.9 kg + measuring probe: 0.7 kg/m 

(6.4 lb + m. probe: 0.47 lb/ft) 

*Details of non-standard floats can be found under “2.2 Float Selection”. 

 

Содержание Nivotrack MI-5 Series

Страница 1: ...mia505en2102p 1 16...

Страница 2: ...mia505en2102p 2 16...

Страница 3: ...mia505en2102p 3 16...

Страница 4: ...mia505en2102p 4 16...

Страница 5: ...RDERED 8 2 2 FLOAT SELECTION 8 3 TECHNICAL DATA 9 3 1 MEASUREMENT DATA MSZ EN 60770 1 2011 MSZ EN 61298 1 2009 MSZ EN 61298 3 2009 10 3 2 DIMENSIONS 11 3 3 ACCESSORIES 12 4 INTEGRATION INTO THE TECHNO...

Страница 6: ...uracy measurement of clean fluids Operating principle The magnetostrictive transmitter is using the special feature of the magnetostrictive wire spanned in the rigid probe A magnetic field excited in...

Страница 7: ...Y 1 BSP lower connection B 1 1 3 3 0 1 0 33 1 Transmitter with plastic coating X 2 BSP C 2 2 6 6 0 2 0 66 2 2 BSP lower connection F 3 3 10 0 3 1 3 1 NPT D 0 4 1 33 4 1 NPT lower connection E 0 5 1 6...

Страница 8: ...dium density Specific gravity 0 45 kg dm3 0 55 kg dm3 0 8 kg dm3 0 55 kg dm3 0 4 kg dm3 0 4 kg dm3 0 7 kg dm3 0 4 kg dm3 0 8 kg dm3 Material Titanium 1 4404 316L 1 4435 316L Titanium 1 4401 316 PVDF P...

Страница 9: ...cm 95 mm 3 74 float min 0 55 g cm 124 mm 4 88 float min 0 4 g cm PVDF float min 0 7 g cm3 Material of wetted parts Stainless steel 1 4571 316Ti floats see Float Selection PFA PVDF PP Ambient temperatu...

Страница 10: ...ce conditions Hysteresis under reference conditions 0 25 mm 0 01 Zero span in LEVEL measurement mode Anywhere within the active range Measurement range reducing Minimal range 32 mm 1 26 Maximum range...

Страница 11: ...mia505en2102p 11 16 3 2 DIMENSIONS STANDARD VERSION MI 5 M MINI VERSION MY 5 M MIF MIH MIU MYB MXU...

Страница 12: ...l as the calculations should be checked carefully Prior to the installation a preliminary operation check is suggested If necessary to change the default factory settings the programming should be per...

Страница 13: ...rrent output does not match device set program lit 1 short term non lighting saturation Parameters can set using a HART modem EView2 or PACTware program or MultiCONT process controller Parameters are...

Страница 14: ...rement range needs to be decreased virtually The absolute value of this number shall be less than the active measurement range Wrong configuration of the zero point offset can result negative level di...

Страница 15: ...ndication by the current output a 0 HOLD Error indication has no effect on the output current In this case it holds the last valid measurement result at the output a 1 3 8 mA Error indication the outp...

Страница 16: ...andling Form must be enclosed Download it from our website www nivelco com The device must be sent with a declaration of decontamination Please provide a statement in the declaration that the decontam...

Отзывы: