MAINTENANCE AND REPAIR 

NIVOTRACK M



–5



 units do not require maintenance on a regular basis. The warranty conditions are included in the warranty card. 

Before returning the device for repairs, it must be cleaned carefully, the parts in contact with the medium that might contain harmful substances must be 
decontaminated. Our official form (

Returned Equipment Handling Form

) must be enclosed. Download it from our website 

www.nivelco.com

. The device must 

be sent with a declaration of decontamination. Please provide a statement in the declaration that the decontamination process is completed, the device is 
clean and free from harmful materials, and there are no hazardous substances on it. 

7.

 

STORAGE CONDITIONS 

 
Unused devices must be stored within the ambient temperature range specified in the technical data, and a maximum of 98% relative humidity. 

 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 

mia505en2102p 

June 2021 

NIVELCO reserves the right to change technical data without notice! 

Содержание Nivotrack MI-5 Series

Страница 1: ...mia505en2102p 1 16...

Страница 2: ...mia505en2102p 2 16...

Страница 3: ...mia505en2102p 3 16...

Страница 4: ...mia505en2102p 4 16...

Страница 5: ...RDERED 8 2 2 FLOAT SELECTION 8 3 TECHNICAL DATA 9 3 1 MEASUREMENT DATA MSZ EN 60770 1 2011 MSZ EN 61298 1 2009 MSZ EN 61298 3 2009 10 3 2 DIMENSIONS 11 3 3 ACCESSORIES 12 4 INTEGRATION INTO THE TECHNO...

Страница 6: ...uracy measurement of clean fluids Operating principle The magnetostrictive transmitter is using the special feature of the magnetostrictive wire spanned in the rigid probe A magnetic field excited in...

Страница 7: ...Y 1 BSP lower connection B 1 1 3 3 0 1 0 33 1 Transmitter with plastic coating X 2 BSP C 2 2 6 6 0 2 0 66 2 2 BSP lower connection F 3 3 10 0 3 1 3 1 NPT D 0 4 1 33 4 1 NPT lower connection E 0 5 1 6...

Страница 8: ...dium density Specific gravity 0 45 kg dm3 0 55 kg dm3 0 8 kg dm3 0 55 kg dm3 0 4 kg dm3 0 4 kg dm3 0 7 kg dm3 0 4 kg dm3 0 8 kg dm3 Material Titanium 1 4404 316L 1 4435 316L Titanium 1 4401 316 PVDF P...

Страница 9: ...cm 95 mm 3 74 float min 0 55 g cm 124 mm 4 88 float min 0 4 g cm PVDF float min 0 7 g cm3 Material of wetted parts Stainless steel 1 4571 316Ti floats see Float Selection PFA PVDF PP Ambient temperatu...

Страница 10: ...ce conditions Hysteresis under reference conditions 0 25 mm 0 01 Zero span in LEVEL measurement mode Anywhere within the active range Measurement range reducing Minimal range 32 mm 1 26 Maximum range...

Страница 11: ...mia505en2102p 11 16 3 2 DIMENSIONS STANDARD VERSION MI 5 M MINI VERSION MY 5 M MIF MIH MIU MYB MXU...

Страница 12: ...l as the calculations should be checked carefully Prior to the installation a preliminary operation check is suggested If necessary to change the default factory settings the programming should be per...

Страница 13: ...rrent output does not match device set program lit 1 short term non lighting saturation Parameters can set using a HART modem EView2 or PACTware program or MultiCONT process controller Parameters are...

Страница 14: ...rement range needs to be decreased virtually The absolute value of this number shall be less than the active measurement range Wrong configuration of the zero point offset can result negative level di...

Страница 15: ...ndication by the current output a 0 HOLD Error indication has no effect on the output current In this case it holds the last valid measurement result at the output a 1 3 8 mA Error indication the outp...

Страница 16: ...andling Form must be enclosed Download it from our website www nivelco com The device must be sent with a declaration of decontamination Please provide a statement in the declaration that the decontam...

Отзывы: