htk4014a600p_04
14/68
3.1.3.
INMETRO Approval No.: DNV 14.0169 X – Rev. 01.
For intrinsically safe [Ex ia] protection modes
Type
Metal housing
with SAP display
HB
–
–6, –8Ex
Metal housing
without SAP display
HT
–
–6, –8Ex
High temperature version with metal
housing with SAP display
HP
–
–6, –8Ex
High temperature version with metal
housing without SAP display
HH
–
–6, –8Ex
Ex marking
(IECEx, INMETRO)
Ex ia IIB T6…T3 Ga
IIC T6…T3 Ga
Ex ia IIB T6…T3 Ga
Ex ia IIC T6…T3 Ga
Ex ia IIIC T100°C Da
Ex power supply,
Intrinsically safety data
Ci
≤
10 nF, Li
≤
10
H, Ui
≤
30 V,
Ii
≤
140 mA, Pi
≤
1 W
3.1.4.
EAC Approval No.: RU C-HU.M
Ю
62.B.04400
For intrinsically safe [Ex ia] protection modes:
Type
Metal housing
with SAP display
HB
–
–6, –8Ex
Metal housing
without SAP display
HT
–
–6, –8Ex
High temperature version with metal
housing with SAP display
HP
–
–6, –8Ex
High temperature version with metal
housing without SAP display
HH
–
–6, –8Ex
Ex marking (EAC)
0Ex ia IIB «T6…T3» Ga X
0Ex ia IIC «T6…T3» Ga X
0Ex ia IIB «T6…T3» Ga X
0Ex ia IIC «T6…T3» Ga X
Ex ia IIIC «T85°C…T110°C»
Da X
Ex ia IIIC «T85°C…T180°C»
Da X
Ex power supply,
Intrinsically safety
data
Ci
≤
10 nF, Li
≤
10
H, Ui
≤
30 V,
Ii
≤
140 mA, Pi
≤
1 W
Ci
≤
10 nF, Li
≤
10
H, Ui
≤
30 V,
Ii
≤
100 mA, Pi
≤
0,75 W
Ci
≤
10 nF, Li
≤
10
H, Ui
≤
30 V,
Ii
≤
140 mA, Pi
≤
1 W
Ci
≤
10 nF, Li
≤
10
H, Ui
≤
30 V,
Ii
≤
100 mA, Pi
≤
0,75 W
For dust protection by enclosure [Ex tD] protection modes:
Type
Metal housing
HB
–
–5Ex
HT
–
–5Ex
High temperature version with metal housing
HP
–
–5Ex
HH
–
–5Ex
Ex marking (ATEX)
Ex ta IIIC «T85°C…T110°C» Da X
Ex tb IIIC «T85°C…T110°C» Db X
Ex ta IIIC «T85°C…T180°C» Da X
Ex tb IIIC «T85°C…T180°C» Db X
Ex power supply,
Intrinsically safety data
Ui = 12.5 – 30 V DC
Содержание MicroTREK HB