35
EN
Adjusting the screw fastening confirmation time
During the screw fastening confirmation time, you can reverse screw tightening. Use this period for rework time or
confirmation work time.
The main LED lights in green during the screw fastening confirmation time, and when the OK signal (output signal
issued when a series of work is completed) is output after the screw fastening confirmation time, the main LED lights
in blue.
Also, by pressing the [UP] button during the screw fastening confirmation time, the OK signal is output by skipping the
screw fastening confirmation time.
1
In screw fastening mode, press and hold the [MEMORY] button and [SELECT] button
The mode enters function setting mode.
2
Press the [SELECT] button to select function No. 4
3
Use the [UP] button or [DOWN] button to change the screw fastening confirmation time (0 - 9.9
sec.)
4
Press the [SELECT] button to select function No. 5
5
Use the [UP] button or [DOWN] button to change the OK signal output timing to “0”
6
Press and hold the [MEMORY] button to save the setting
Timing chart
When function No. 1 (workpiece signal) is set to “1: Input”, the timing chart is different. See “Adjusting the OK signal
output” (p. 52).
1
1
2
3
9
2
4
7
8
8
7
4
5
6
3
MAIN LED
MAIN LED
MAIN LED
MAIN LED
When the [UP] button is not pressed
When the [UP] button is pressed
1
Screw tightening
2
Completion of screw
tightening set count
3
OK signal 0.1 sec.
4
Screw fastening
confirmation time
5
Time until the [UP] button
is pressed
6
Time skipped
7
Lights in green
8
Lights in blue
9
Press the [UP] button
TV07521-1_DLV30S12P-AYK_en.indb 35
2017/02/10 15:56:35