29
EN
Timing chart
When the torque reaches the set torque during reverse rotation in auto reverse mode, NG occurs and the parameter
LED displays E4.
When the start switch is released during reverse rotation in auto reverse mode, NG occurs and the parameter LED
displays E5.
When the setting is “Reverse after the lower limit of screw fastening time” in auto reverse mode, if the torque reaches
the set torque during reverse rotation NG occurs and the parameter LED displays E6.
Motion
No.
Setting
Setting condition:
Reverse after torque-up
Setting condition for
Reverse after lower limit of
screw fastening time
Setting condition for
Stop at lower limit of screw
fastening time
9
Auto reverse mode
setting
1
2
2
10
Reverse speed level
Optional
Optional
Optional
11
Reverse rotation time
Optional
Optional
0 sec.
Reverse after torque-up
1
2
3
4
5
6
7
a
0
8
9
b
c
Speed
Time
1
Middle
2
Reverse rotation
3
Finish
4
Start
5
Torque-up
6
Reverse rotation starts
7
Stop
8
Rotation time at start
9
Rotation time at middle
0
Lower limit of screw fastening
time
a
Upper limit of screw fastening
time
b
0.2 sec.
c
Reverse rotation time
Reverse after the lower limit of screw fastening time
1
2
3
4
5
6
7
0
8
9
a
b
1
Middle
2
Reverse rotation
3
Finish
4
Start
5
Torque-up
6
Reverse rotation start
7
Stop
8
Rotation time at start
9
Rotation time at middle
0
Lower limit of screw fastening
time
a
0.2 sec.
b
Reverse rotation time
* Stop at the lower limit of screw
fastening time
Speed
Time
* About “Stop at reverse after the lower limit of screw fastening time”, see the next page.
TV07521-1_DLV30S12P-AYK_en.indb 29
2017/02/10 15:56:34