eNCard-i User guide
60
NITGEN Co., Ltd. /
(Bangi-dong) 6 Wiryeseong-daero, Songpa-gu, Seoul, 138-827, Korea
Tel: 02-6488-3052, Fax: 02-6488-3098, E-Mail:[email protected]
If you select the [Terminal]->[External device] in the main menu, the following window
appears.
▶
Default Setting: Same as the window on the left.
▶
Site code
It sets the sitecode value sent in Wiegand output below.
When the authorization is successful, the data of the
following format is sent to the Wiegand port of the
terminal.
▶
Wiegand Input
Standard wiegand is 26 or 34 bit. The terminal is always
waiting for wiegand input, up to 34 bits.
Use Terminal option, card reading to view the card number
received at the wiegand input. If the format of the data is
incorrect it must be setup using the server program
.
▶
Wiegand Output
This is only used when connecting the terminal to an external controller to notify the controller
with card data or user id that was used. Standard wiegand output is 26 or 34 bit. If any other
format is needed, the setup must be done using the server program.
Wiegand Output type can be set for User ID, Card Number or Unique ID.
None
General case. It does not use Wiegand out port.
26bit
Sending “Sitecode[1byte] + User ID[2 byte]”, set the user ID less or
equal than 4 digits.
Send example) In case of SiteCode:045(2Dh), UID:6543(198Fh)
1 00101101 0001 1001 10001111 0
34bit
Sending “Sitecode[1 byte] + User ID[3 byte]”, set the user ID less or
equal than 7 digits.
But, if the user ID is 8 digits, ignore sitecode and send only the “User
ID[4byte]”.
Send example) SiteCode:001(1h), UID:123456(1E240h)
0 00000001 00000001 11100010 01000000 0
Custom
When the server program sets the wiegand output to other value than
the standard 26/34 bit, this is displayed. This type can only be selected
and setup using the server program.
Select the [OK] button to save the value or select [BACK] button to cancel and return.