140
MOTOR
9
Side cover(R)
Motor bracket
Lead wire
Hydraulic motor
High pressure hose
Low pressure hose
2210096
: Tightening torque
l
Removing the hydraulic motor (1)
l
Fitting bolt(*1)
9-2-2. Hydraulic motor - removal and installation
CAUTION
l
Before disconnecting hydraulic connections, release internal pressure
to prevent from splashing oil.
Refer the CAUTION on the page 4 for the procedure.
l
When disconnecting hydraulic pipes, cap them to prevent dust from
entering into hydraulic components and pipes.
l
Be sure to disconnect the battery plug.
Remove the cover ASS'Y, battery.
Remove the battery ASS'Y
Remove fitting bolt for the motor bracket, and hoist the
hydraulic motor with the motor bracket.
Disconnect lead wires on the hydraulic motor.
Disconnect following hoses from the pump.
(1) High pressure hose [come from the Control valve]
(2) Low pressure hose [come from the Oil tank]
1.
2.
3.
4.
5.
Tightening torque
29.4 - 39.2 N
m
{3 - 4 kgf
m}