56041474
Warning: these operations must be carried
out with the machine off and the key
switched off. All periodic or extraordinary
maintenance operations must be performed
by skilled personnel, or by an authorised
service centre.
Note
:
The battery duration will depend on the level
of periodic maintenance (checking the
electrolyte level and density).
If the machine does not run for a long time
(ex. 4 to 6 weeks) it will be necessary to
recharge the batteries to make sure their
voltage does not go under 20 Volt. Unused
batteries discharge themselves.
MAINTENANCE
17
CONTROL
UPON
DELIVERY
EVERY
50/h
EVERY
100/h
EVERY
200/h
Battery liquid level and
voltage level
•
•
Check the brushes of all
electric motors, and replace
them if worn.
•
Belt tension
•
•
Brake adjustment
•
•
Filter shaker
•
Nut and screw tightness
•
Side and centre brush condi-
tion
•
Cartridge filter cleaning
•
Bin gasket seal
•
•
GREASE:
Drive wheel chain
•