56041474
Insert the ignition key into the panel and turn
it clockwise. After 3 seconds the battery
charge condition will appear on the display.
The display has two functions: voltmeter and
hour meter.
The voltmeter will activate the block function
during an undervoltage and will disable all
machine activities except for the drive when
the battery voltage drops below 20 volts (the
display flashes).
At 19 Volts the machine is totally blocked
including the drive. Recharge the battery as
described on page 7 and 8.
NOTE
: If the machine must be moved,
disconnect the ignition key, and push it slowly
backwards. If the distance is farther than 10
metres lift up the front traction wheel.
To access the hour meter function, press the
button indicated in the figure and the display
will show the number of machine service
hours. Press the button again to display the
number of machine service minutes.
After 10 seconds the value on the display will
return automatically to the battery voltage
level.
If the electronic circuits malfunction, the
display indicates an error code that
corresponds to the type of fault and the
machine stops. (See the TROUBLESHOOTING
chapter for the error code table).
Start the centre brush using the button shown
in the figure - the relative lamp turns on
indicating that the brush is operating.
Press the button again to deactivate the
brush.
NOTE
: When the centre brush is activated the
suction function is activated as well.
START-UP