RECOVERY SYSTEM
TROUBLESHOOTING GUIDE
Possible Symptom
1
Squeegee will not raise or lower.
Part A:
Note: Do all testing with the key switch ON, recovery tank empty and the hopper closed. Squeegee switch must be activated on the display
panel.
Squeegee will not raise
or lower
Press the squeegee switch. Is
its green indicator light on?
Substitute a new A2
display panel.
Does squeegee operate?
Check for 12 volts inputs at L1
and L2 coils, wire colors
(+)ORG L1 and L2
(-) L1 BLU/WHT
(-) L2 ORG/RED
Repair or replace wiring
to coils
Does squeegee oper-
ate?
Check for coil resistance at
L1 and L2 (9 ohm)
Replace defective coil.
Does squeegee operate?
See Hydraulic squeegee
troubleshooting section
Part B
Yes
Yes
Yes
No
No
No
Press the squeegee button,
then observe the green lights
on the A1 relay board.
down: S1 (momentary) S2 on
up: S2 off S1 (momentary)
Replace A1 control
board.
Does squeegee oper-
ate?
No
Yes
No
No
No
No
Содержание Captor 4300
Страница 13: ...FORM NO 56043093 Captor 4300 4800 5400 11 THIS PAGE IS INTENTIONALLY BLANK ...
Страница 68: ...66 FORM NO 56043093 Captor 4300 4800 5400 ENGINE SYSTEM FIGURE 4 TIER II revised 7 08 ...
Страница 74: ...72 FORM NO 56043093 Captor 4300 4800 5400 HYDRUALIC SYSTEM ...
Страница 75: ...FORM NO 56043093 Captor 4300 4800 5400 73 HYDRAULIC SYSTEM ...
Страница 88: ...86 FORM NO 56043093 Captor 4300 4800 5400 ELECTRICAL SYSTEM THIS PAGE IS INTENTIONALLY BLANK ...
Страница 102: ...100 FORM NO 56043093 Captor 4300 4800 5400 AXP EDS SYSTEM revised 12 08 ...
Страница 107: ......
Страница 108: ......