- FORM NO. 56043093 / Captor
™
4300, 4800, 5400
SCRUB SYSTEM
TROUBLESHOOTING GUIDE
Possible Symptom
1
Scrub deck motor(s) will not operate
Part B: Hydraulic
Note: All tests should be done with the scrub deck lowered, drive pedal activated and engine running in high speed (2400 rpm).
*Note: See hydrualic sysem manual section for more troubleshooting information.
All the scrub brush motors
will not turn.
Are the scrub deck and
squeegee in their lowered
position?
*Insert a pressure gauge at
the XT3 pressure fitting.
Does the (1B) relief valve
found on main relief valve
block open at 2400 PSI?
No
Check for debris wrapped
around the motor shafts.
Repair or replace
individual defective
motor.
Do the motors run?
No
Remove and disassemble L7
scrub motor spool valve
(cartridges). Inspect, clean
and reinstall.
Do the motors turn?
Replace defective
spool valve L7
No
Scrub deck motor(s) will
not operate
No
Yes
Repair or replace
individual defective motor.
Adjust, clean or replace
1B relief valve.
Do the motors run?
Yes
No
No
No
Yes
Remove debris.
Do the motors run?
No
Содержание Captor 4300
Страница 13: ...FORM NO 56043093 Captor 4300 4800 5400 11 THIS PAGE IS INTENTIONALLY BLANK ...
Страница 68: ...66 FORM NO 56043093 Captor 4300 4800 5400 ENGINE SYSTEM FIGURE 4 TIER II revised 7 08 ...
Страница 74: ...72 FORM NO 56043093 Captor 4300 4800 5400 HYDRUALIC SYSTEM ...
Страница 75: ...FORM NO 56043093 Captor 4300 4800 5400 73 HYDRAULIC SYSTEM ...
Страница 88: ...86 FORM NO 56043093 Captor 4300 4800 5400 ELECTRICAL SYSTEM THIS PAGE IS INTENTIONALLY BLANK ...
Страница 102: ...100 FORM NO 56043093 Captor 4300 4800 5400 AXP EDS SYSTEM revised 12 08 ...
Страница 107: ......
Страница 108: ......