![Nilfisk-Advance Captor 4300 Скачать руководство пользователя страница 42](http://html.mh-extra.com/html/nilfisk-advance/captor-4300/captor-4300_quick-start-troubleshooting-manual_1692992042.webp)
40
- FORM NO. 56043093 / Captor
™
4300, 4800, 5400
HOPPER SYSTEM
TROUBLESHOOTING GUIDE
Possible Symptom
1
Hopper dump door will not open in dump mode.
Part A:
Note: Do all testing with Key Switch ON, hopper raised (engine must be run to raise hopper).
Press and hold dump door
open switch. Is the green light
on the A1 board S11 relay.
Check for 12 volts at L11
Dump Door coil. Wire color
(+) ORN, (-) BLK/WHT
Check for coil resistance at
L11 (9 ohm)
See hydraulic dump door
troubleshooting section
Part B
Repair or replace L11 coil
No
No
Yes
No
Yes
Replace the
A1 Control board
No
Yes
Yes
Repair or replace L11 coil
wiring
No
Yes
Substitute a new A2 Display
panel. Does dump door
operate?
Repair or replace (S12)
switch wiring.
Does door open?
Yes
Yes
No
Dump Door will not open
Check if the hopper raise
indicator light is flashing
on A2 panel
Check continuity and
adjustment of hopper raise
switch (S12)
Note: Switch will check
open when hopper is
raised
Repair or replace (S12)
switch.
Press and hold dump door
open switch, is its green
indicator light on
Check (S12) switch wiring
for a short
Replace A2 control panel
display
No
No
Содержание Captor 4300
Страница 13: ...FORM NO 56043093 Captor 4300 4800 5400 11 THIS PAGE IS INTENTIONALLY BLANK ...
Страница 68: ...66 FORM NO 56043093 Captor 4300 4800 5400 ENGINE SYSTEM FIGURE 4 TIER II revised 7 08 ...
Страница 74: ...72 FORM NO 56043093 Captor 4300 4800 5400 HYDRUALIC SYSTEM ...
Страница 75: ...FORM NO 56043093 Captor 4300 4800 5400 73 HYDRAULIC SYSTEM ...
Страница 88: ...86 FORM NO 56043093 Captor 4300 4800 5400 ELECTRICAL SYSTEM THIS PAGE IS INTENTIONALLY BLANK ...
Страница 102: ...100 FORM NO 56043093 Captor 4300 4800 5400 AXP EDS SYSTEM revised 12 08 ...
Страница 107: ......
Страница 108: ......