SOLUTION SYSTEM
TROUBLESHOOTING GUIDE
Possible Symptom
1
Solution solenoid valve does not operate
Electrical
Note: Do all testing with the key switch turned ON, solution switch button depressed, scrub system activated and the drive pedal moved into
the
FORWARD
direction.
Solution solenoid valve does
not work
Press the solution button on the
operator A2 panel. Is the green
indicator light on?
Substitute a new A2
display panel. Does the
solution solenoid operate?
Check for 12V at the L16 sole-
noid coil, wire colors (+) ORG
& (-) YEL/GRN
Repair or replace wiring to
the solenoid valve.
Does the solution solenoid
operate?
Check the L16 solenoid coil
resistance it should read
7-9 Ohms.
Replace the L16 coil as it tests
either open or shorted.
Yes
Yes
Yes
No
No
No
Press the solution button and
check on the A1 control board
to see if the green L16 solution
relay indicator light is on.
Replace the A1 control board.
Does solution solenoid
operate?
No
Yes
Disassemble and clean the
solution valve body and retest.
If it still does not operate
replace with a new L16 solu-
tion solenoid valve assembly
No
No
No
Содержание Captor 4300
Страница 13: ...FORM NO 56043093 Captor 4300 4800 5400 11 THIS PAGE IS INTENTIONALLY BLANK ...
Страница 68: ...66 FORM NO 56043093 Captor 4300 4800 5400 ENGINE SYSTEM FIGURE 4 TIER II revised 7 08 ...
Страница 74: ...72 FORM NO 56043093 Captor 4300 4800 5400 HYDRUALIC SYSTEM ...
Страница 75: ...FORM NO 56043093 Captor 4300 4800 5400 73 HYDRAULIC SYSTEM ...
Страница 88: ...86 FORM NO 56043093 Captor 4300 4800 5400 ELECTRICAL SYSTEM THIS PAGE IS INTENTIONALLY BLANK ...
Страница 102: ...100 FORM NO 56043093 Captor 4300 4800 5400 AXP EDS SYSTEM revised 12 08 ...
Страница 107: ......
Страница 108: ......