![Nilfisk-Advance Captor 4300 Скачать руководство пользователя страница 47](http://html.mh-extra.com/html/nilfisk-advance/captor-4300/captor-4300_quick-start-troubleshooting-manual_1692992047.webp)
FORM NO. 56043093 / Captor
™
4300, 4800, 5400 -
45
SCRUB SYSTEM
TROUBLESHOOTING GUIDE
Possible Symptom
1
Scrub deck will not operate in pressure setting (2)
Part A: Electrical Control Circuit
Note: Do all testing with the key switch ON, scrub deck pressure set on (2) by depressing the scrub increase switch on the A2 display panel.
Scrub deck will not function in
pressure setting (2)
Press and release scrub
increase switch (+) until 2 appears in
the display.
Is its green indicator light on?
Substitute a new A2
display panel.
Does the deck lower?
Check for 12 volts at coils
•
L3 (+) ORG (-) BRN
•
L5 (+) ORG (-) WHT/VIO
•
L15 (+) ORG (-) GRN/VIO
Repair or replace
defective coil wiring.
Does the deck lower?
Check for coil resistance
at L3, L5 & L15 (9 ohm)
Replace defective coil(s).
Does the deck lower?
See Hydraulic scrub deck troubleshoot-
ing section Part B position 2.
Yes
Yes
Yes
No
No
No
Press the scrub off switch then scrub
increase switch (may need to be
cycled to observe lights) observe the
green lights on the A1 board S3, S5 &
S15 are they on?
Replace A1 control
board.
Does the deck lower?
No
Yes
No
No
No
No
Содержание Captor 4300
Страница 13: ...FORM NO 56043093 Captor 4300 4800 5400 11 THIS PAGE IS INTENTIONALLY BLANK ...
Страница 68: ...66 FORM NO 56043093 Captor 4300 4800 5400 ENGINE SYSTEM FIGURE 4 TIER II revised 7 08 ...
Страница 74: ...72 FORM NO 56043093 Captor 4300 4800 5400 HYDRUALIC SYSTEM ...
Страница 75: ...FORM NO 56043093 Captor 4300 4800 5400 73 HYDRAULIC SYSTEM ...
Страница 88: ...86 FORM NO 56043093 Captor 4300 4800 5400 ELECTRICAL SYSTEM THIS PAGE IS INTENTIONALLY BLANK ...
Страница 102: ...100 FORM NO 56043093 Captor 4300 4800 5400 AXP EDS SYSTEM revised 12 08 ...
Страница 107: ......
Страница 108: ......