FORM NO. 56043093 / Captor
™
4300, 4800, 5400 -
35
SWEEPING SYSTEM
TROUBLESHOOTING GUIDE
Possible Symptom
1
Shaker motor will not run
Electrical Circuit
Note1: Before testing first confirm that the 10Amp F7 circuit breaker is good.
Note2: Do all testing with the key switch turned ON.
Shaker motor will not run
Press the shaker button on the
operator A2 panel. Is the upper
left green indicator light on?
Substitute a new A2 display
panel.
Does shaker motor operate?
Check for 12V at the K3 shaker
relay coil, wire colors (-) GRN
& (+) ORG
Repair or replace wiring to
coil.
Does shaker motor operate?
Check the K3 coil resistance
should measure
370 Ohms + or - 10%
Replace the defective
K3 relay.
Does shaker motor operate?
Yes
Yes
Yes
No
No
No
Press shaker switch button
and check on the A1 control
board to see if the shaker
relay green indicator light is
on.
Replace A1 control board.
Does shaker motor
operate?
No
Yes
Check for 12V at the shaker
motor, wire colors
BLU/GRN & BLK
Replace the defective K3
relay or wiring.
Does shaker motor operate?
Yes
No
Test for 12V (+) at the K3 relay
load terminals
•
(output #87) BLU/GRN to
battery ground
•
(input #30) BLU/YEL to bat. GND
Repair or replace
motor wiring.
Does shaker motor operate?
Yes
No
Replace the M2 shaker motor
No
No
No
No
No
No
Содержание Captor 4300
Страница 13: ...FORM NO 56043093 Captor 4300 4800 5400 11 THIS PAGE IS INTENTIONALLY BLANK ...
Страница 68: ...66 FORM NO 56043093 Captor 4300 4800 5400 ENGINE SYSTEM FIGURE 4 TIER II revised 7 08 ...
Страница 74: ...72 FORM NO 56043093 Captor 4300 4800 5400 HYDRUALIC SYSTEM ...
Страница 75: ...FORM NO 56043093 Captor 4300 4800 5400 73 HYDRAULIC SYSTEM ...
Страница 88: ...86 FORM NO 56043093 Captor 4300 4800 5400 ELECTRICAL SYSTEM THIS PAGE IS INTENTIONALLY BLANK ...
Страница 102: ...100 FORM NO 56043093 Captor 4300 4800 5400 AXP EDS SYSTEM revised 12 08 ...
Страница 107: ......
Страница 108: ......