Service Manual-AS1050R
04 Control System 43
Main Controller (EB2) Parameter Setting
NO. Parameter Name Value
Unit
Comment
F6
Wat-Emp ValOff
0
N/A
Solution tank empty valve off. 0-Not off
F7
Wat-Emp BruOff
0
N/A
Solution tank empty brush off. 0-Not off
F8
Dir-Full VavOff
0
N/A
Recovery tank full valve off. 0-Not off
F9
Dir-Full VacOff
1
N/A
Recovery tank full vacuum motor off. 0-Not off, 1-Off
G0 Chat Time
0
Minute
Enter sleep mode time. 0-Not sleep
G1 Battery Type
0
N/A
Battery type. 0-Lead acid, 1-Lithium-ion.
G2 C0 Volt
18
V
Reserved
G3 C1 Volt
18
V
Reserved
G4 C2 Volt
20
V
Reserved
G5 C3 Volt
22
V
Reserved
G6 C4 Volt
28
V
Reserved
G7 C5 Volt
26.8
V
Reserved
G8 Trial Tim Lim
0
Hours
Reserved
G9 Used Trial Time
0
Hours
Reserved
H0 Turn Spd Decel-1
2
Seconds
Transport mode. Turning deceleration rate 1
H1 Turn Spd Perc-1
65
%
Transport mode. Turning deceleration percentage 1
H2 Turn Spd Decel-2
2
Seconds
Transport mode. Turning deceleration rate 2
H3 Turn Spd Perc-2
45
%
Transport mode. Turning deceleration percentage 2
H4 Pressure L1-L2
1.2
Seconds
Brush down time from brush pressure level 1 to level 2
H5 Pressure L2-L3
1.3
Seconds
Brush down time from brush pressure level 2 to level 3
H6 Pressure L2-L1
1
Seconds
Brush up time from brush pressure level 2 to level 1
H7 Pressure L3-L2
1.2
Seconds
Brush up time from brush pressure level 3 to level 2
H8 Scr TrdSpd Dec-1
2
Seconds
Work mode. Turning deceleration rate 1
H9 Scr TrdSpd Red-1
65
%
Work mode. Turning deceleration percentage 1
I0
Scr TrdSpd Dec-2
2
Seconds
Work mode. Turning deceleration rate 2
I1
Scr TrdSpd Red-2
40
%
Work mode. Turning deceleration percentage 2
I2
Min TrdSpd Dec
9
V
Traction motor minimum voltage for turning deceleration
function (If lower than this voltage, no turning deceleration)
I3
ECO TrdSpd Dec-1
2
Seconds ECO mode. Turning deceleration rate 1
I4
ECO TrdSpd Red-1
65
%
ECO mode. Turning deceleration percentage 1
I5
ECO TrdSpd Dec-2
2
Seconds ECO mode. Turning deceleration rate 2
I6
ECO TrdSpd Red-2
40
%
ECO mode. Turning deceleration percentage 2
Содержание 50000593
Страница 11: ...Service Manual AS1050R 03 General Information 11 Machine Structure Figure 2 ...
Страница 12: ...Service Manual AS1050R 03 General Information 12 Machine Structure continues Figure 3 ...
Страница 13: ...Service Manual AS1050R 03 General Information 13 Control Panel Figure 4 ...
Страница 15: ...Service Manual AS1050R 03 General Information 15 Dimensions continues ...